2kVA Online Transformer-less UPS

Norden's Maxpower Series 2 kVA UPS is an online double conversion UPS that features a single phase in both input and output, and an output power factor of 0.9. This tower-type UPS is designed to be used in commercial buildings and offices, and can be connected to desktops and servers.

Norden's Maxpower Series 2 kVA UPS is an online double conversion UPS that features a single phase in both input and output, and an output power factor of 0.9. This tower-type UPS is designed to be used in commercial buildings and offices, and can be connected to desktops and servers

General Features

  • High power density
  • Online double conversion with full digital control
  • Selectable output voltage:220/230/240Vac
  • Wide input voltage range:110~300Vac
  • Input power factor 0.99 with PFC
  • Maximum charging current up to 12A (long run unit)
  • Emergency power OFF function
  • ECO mode operation for energy saving
  • Multiple communication interface:RS232 (USB/Dry contact/SNMP card optional)
  • Self-testing when UPS start-up
  • Generator compatible
  • Cold start
  • Intelligent fan speed regulation
  • Outlet socket universal (optional) 

Specification

ModelCN7002MPI/CN7002MPE

Capacity

VA

2000

Watts

1800

Phase

Single phase with ground

Input

Normal Voltage

208/220/230/240Vac
Operating Voltage Range
110~300Vac

Frequency Range

45~55Hz/55~65Hz (Auto-detect)

Power Factor

≥0.99 @Nominal voltage(100% load)

Output

Output Voltage

208/220/230/240Vac

Power Factor

0.9

Voltage Regulation

±1%

Frequency

Line mode
(Synchronized range)

46~54Hz / 56~64Hz

Bat. mode

50Hz / 60Hz ±0.1Hz

Crest Factor

3:1

Harmonic Distortion (THDv)

≤3% THD(Linear load)

≤5% THD(Non-linear load)

Transfer time

AC to DC

Zero

Inverter to bypass

4ms(Typical)

Waveform

Pure sinewave

Efficiency

AC Mode

90%

Battery Mode

87%

Battery

Internal

Battery Type

12V/9AH

Numbers

6

Typical Recharging Time

4 hours recover to 90% capacity

Charging current(max.)

1A

Charging Voltage

82.1Vdc ±1%

Battery

External

Battery Numbers

6
Charging Voltage 
82.1Vdc ±1%

Charging  Current

12A

Indicators

LCD 

Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators

Alarm

Battery Mode

Beeping every 4 seconds

Battery Low

Beeping every second

Overload

Beeping twice every second

Fault

Continuously beeping

Physical

Dimension

W x D x H (mm)

Standard model

440x460x86.5/440x600x86.5

Long run model

440x600x86.5

Weight (kg)

Standard model

19.5/25

Long run model

10.5

Environment

Humidity

20-90% RH @ 0-40°C (Non-condensing)

Noise level

<50dB @ 1 Meter

Management

Smart RS232/USB

Supports Windows® 7/8/10, Linux, FreeBSD and MAC

Optional SNMP

Power management from SNMP manager and web browser

Standards

Safety

IEC/EN62040-1,IEC/EN62477-1

EMC

IEN/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8,IEC61000-4-11,IEC61000-2-2

Specifications are subject to change without prior notice.

EXTERNAL BATTERY PACK

ModelCNBC00272CT
BATTERY SYSTEM

Battery Type

VRLA (Valve Regulated Lead Acid Battery - SMF)

Typical battery recharging time
6~8 hours (to 90% of full capacity)
Typical Battery Life3~5 years, depend on discharging cycle and ambient temperature

System Voltage

48Vdc

72Vdc

Charging Current Max1.4A
Battery Qty812

Capacity

9Ah/12V (7Ah/12V optional

PHYSICAL
Dimension(WxDxH)191 x 460 x 337
Net weight(kg)28.5                                          38.5
ENVIRONMENT
Operating environment
0°C~40°C
Relative humidity
0~95% (Non condensing)
Noise Level<40dB at 1 Meter

                                                                     

Part NumberDescription

CN7002MPI

2kVA Online Transformerless UPS (Internal battery) 

CN7002MPE

2kVAOnline Transformerless UPS (External battery) 

CNBC00248CT

48 VDC Battery Pack

CNBC00272CT

72 VDC Battery Pack

COMPATIBLE ACCESSORIES

Part NumberDescription
CNS02
Mini SNMP Card for 1-10kVA UPS