Norden Category 6 U/UTP armoured cables exceed Category 6 / Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility). minimizing radiation. maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems. Cat 6 UTP armoured Cable Consists of PE Insulated 23AWG Solid Electrolytic Grade Bare Copper Conductors, twisted 4 pair stranded over Cross PE Separator filler. ECCS tape Armour, Inner LSZH and Outer LSZH with Outer jacket have Anti-termite, Pest resistant, Rodent-proof, Corrosion resistant, Immunised from degradation due to atmospheric impurities and environmental conditions.
Norden Category 6 U/UTP armoured cables exceed Category 6 / Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility). minimizing radiation. maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems. Cat 6 UTP armoured Cable Consists of PE Insulated 23AWG Solid Electrolytic Grade Bare Copper Conductors, twisted 4 pair stranded over Cross PE Separator filler. ECCS tape Armour, Inner LSZH and Outer LSZH with Outer jacket have Anti-termite, Pest resistant, Rodent-proof, Corrosion resistant, Immunised from degradation due to atmospheric impurities and environmental conditions.
MATERIAL CONSTRUCTION & DESIGN
Conductor Material | Electrolytic Grade Bare Copper |
Conductor Size | 23 AWG |
Conductor Construction | Solid |
Insulation Material | Polyethylene (HDPE) |
Insulation O.D. | 1.07mm ± 0.05 |
Insulation Thickness | 0.25 ± 0.05mm |
Conductor Unit Identification | Solid/Stripe |
Colour Code | Per TIA/EIA 568-B |
Conductor Unit Lay-Up | Pairs |
Total Number of Wires | 8 |
Separator | PE |
Inner Jacket Material | LSZH |
Inner Jacket Thickness | 0.65 ± 0.10mm |
Inner Jacket Diameter | 6.50 ± 0.30mm |
Armour | ECCS Tape |
Armour Thickness | 0.125mm |
Outer Jacket Material | LSZH with Anti Rodent and Anti Termite |
Outer Jacket property | Anti-termite, Pest resistant, Rodent-proof, Corrosion resistant, Immunised from degradation due to atmospheric impuritiesand environmental conditions |
Outer Jacket Thickness | 1.20 ± 0.10 mm |
Outer Jacket Diameter | 10.40 ± 0.50mm |
Outer Jacket Colour | Black |
Conductor Resistance @20°C | Max. 93.8 Ω/KM |
Conductor Resistance Unbalance | Max. 5 % |
Mutual Capacitance @1KHZ | Max. 5.6 nF/100 m |
Insulation Resistance | Min. 5000 MΩ.km |
High voltage | 1 kV DC/1 min |
Capacitance Earth Unbalance | Max. 3300 pF/km |
Velocity of Propagation | 69 % |
Propagation Delay Skew 1 – 250 MHz | > 8 X D |
Characteristic Impedance (1-250 MHz) | Max. 3300 pF/km |
Bending radius | 69% |
Characteristic Impedance (1-250 MHz) | 100 ± 15Ω |
Bending radius | Min.8 x Outer Diameter |
Pulling Force | 110N |
Temperature Range | - 20° to + 75°C |
Freq. (Mhz) | ATT (dB/100m) max. | NEXT (dB) min. | PS. NEXT (dB) min. | ACRF (dB@100m) min. | PS. ACRF (dB@100m) min. | RL (dB/100m) |
---|---|---|---|---|---|---|
1 | 2.1 | 65.0 | 62.0 | 63.3 | 60.3 | 19.0 |
4 | 4.0 | 63.0 | 60.5 | 51.2 | 48.2 | 19.0 |
8 | 5.7 | 58.2 | 55.6 | 45.2 | 42.2 | 19.0 |
10 | 6.3 | 56.6 | 54.0 | 43.3 | 40.3 | 19.0 |
16 | 8.0 | 53.2 | 50.6 | 39.2 | 36.2 | 18.0 |
20 | 9.0 | 51.6 | 49.0 | 37.2 | 34.2 | 17.5 |
25 | 10.1 | 50.0 | 47.3 | 35.3 | 32.3 | 17.0 |
31.25 | 11.4 | 48.4 | 45.7 | 33.4 | 30.4 | 16.5 |
62.5 | 16.5 | 43.4 | 40.6 | 27.3 | 24.3 | 14.0 |
100 | 21.3 | 39.9 | 37.1 | 23.3 | 20.3 | 12.0 |
200 | 31.5 | 34.8 | 31.9 | 17.2 | 14.2 | 9.0 |
250 | 35.9 | 33.1 | 30.2 | 15.3 | 12.3 | 8.0 |
Part Number | Description | Standard Length |
113-2082I104X | CAT6 U/UTP Double Jacket Steel Tape Armoured Outdoor Cable LSZH | 305 mtr |
X:BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)