2 Core 16 AWG Unshielded Multi Conductor PE External Cable

The Unshielded Multi Conductor Cable from NORDEN is suitable to use within Commercial Audio Systems, Control and Instrumentation purpose. The cable is constructed with PE insulation, Nylon Rip Cord and PVC or LSZH outer jacket.

The Unshielded Multi Conductor Cable from NORDEN is suitable to use within Commercial Audio Systems, Control and Instrumentation purpose. The cable is constructed with PE insulation, Nylon Rip Cord and PVC or LSZH outer jacket.

CABLE CONSTRUCTION

Conductor

Bare Copper

Rip Cord

Nylon

Jacket Color

Black

Insulation

PE (Polyethylene)

Outer Jacket

PE (Polyethylene)

 

PHYSICAL CHARACTERISTICS

Characteristic Value

No. of Conductor

2

Conductor Size

16 AWG 19 x 29

Insulation Thickness

0.18 mm

Insulation Diameter

2.10 mm

Jacket Thickness

0.45 mm

Jacket Diameter

4.50 mm

Max. Recommended Pulling Tension

262 N

Min. Bending Radius Minor Axis

44 mm

Operating Temperature

-10ºC to +75ºC

 


ELECTRICAL CHARACTERISTICS

Characteristic Unit Value

Nom. Capacitance

pF/m

77.1

Nom. Conductor DCR

Ω/km

13.7

Max. Recommended Current @ 25°C

Amps

6.25

Max. Operating Voltage UL

V/min

300

MECHANICAL CHARACTERISTICS

Characteristic Value

Test Material

PE

Before Tensile Strength (Mpa)

≥ 13.8

Aging Elongation (%)

≥ 100

After Tensile Strength (Mpa)

≥ 10.35

Aging Elongation (%)

≥ 75

Cold Bend (-20±°C x 4 hrs)

No Crack

INSULATION COLOUR CODE

Individual Core Colour

Core 1

Black

Core 2

White

Part Number Description Net Weight (Kg/Km)

71-3102164

2 Core 16 AWG Unshielded Multi Conductor PE External Cable, 305m

30