40-80KVA DOUBLE CONVERSION TRANSFORMER-BASED UPS

Norden's Ultra power series 40-80kVA UPS is an online Transformer-based UPS which has three phase in both input and output and an output power factor of 0.9.This UPS Features an isolation transformer in the output side to provide galvanic isolation for the load connected and parallel operation helps to increase redundancy and capacity.

Norden's Ultra power series 40-80kVA UPS is an online Transformer-based UPS which has three phase in both input and output and an output power factor of 0.9.This UPS Features an isolation transformer in the output side to provide galvanic isolation for the load connected and parallel operation helps to increase redundancy and capacity.

GENERAL FEATURES

    • Online Double Conversion
    • Full DSP Control
    • High Power Factor
    • Wide input adaptability
    • Optimized battery management
    • N+X parallel redundancy
    • Strong overload capability
    • Multi-protection
    • Generator mode
    • EPO function 

    Specification

    ModelCN43340TU
    CN43360TU
    CN43380TU 

    Capacity

    kVA

    40kVA

    60kVA
    80kVA

    Watts

    36kW

    54kW
    72kW

    Input

    Normal Voltage380/400/415Vac (3Ph+N+PE) (-25% +20%)
    Operating frequency range
    50/60Hz (±5Hz) 
    Power factor
    0.98 (with filter)
    Bypass voltage range

    Upper limit:+20%(+10%,+15%,+20% adjustable)

    Lower limit:-40%(-10%,-20%,-30%,-40% adjustable)

    Bypass Frequency range
    ±10%(±2.5%,±5%,±10%,±20% adjustable)

    Output

    Rated voltage380/400/415Vac (3Ph+N+PE)
    Power factor
    0.9
    Voltage regulation
    ±1%
    Frequency   
    50/60(±0.05)Hz
    Crest factor
    3:1
    Harmonic distortion (THDv)
    ≤2% with linear load
    Efficiency
    >90%                                                                       >90.5%
    Output Waveform
    Pure Sine Wave

    Battery

    Battery voltage384Vdc (30/32pcs)

    Charging Current36.4A                                        54.5A                             72.6A

    System Features

    Transfer timeMains to battery:0ms;
    Overload  
    110%60min, 125%10min, 150%1min
    LED Display
    Input, Inverter, Bypass, Battery, Output, Status
    LCD Display 
    I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage, UPS status, history record, settings
    Communication 
    USB, RS232, RS485, Parallel port,dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional)

    Environment

    Operating temperature0~40°C
    Storage temperature
    -25~55°C
    Humidity range
    0~95% (Non-condensing)
    Altitude
    <1500m
    Noise level
    <58dB

    Physical

    Dimension WxDxH(mm)430x830x1100                     430x830x1100               720x690x1400                 
    Net Weight (kg)
    255320

    450

    Standards

    SafetyIEC/EN62040-1,IEC/EN62477-1
    EMC

    IEC/EN 62040-2;IEC 61000-2-2;IEC 61000-4-2;IEC 61000-4-3;IEC 61000-4-4 IEC 61000-4-5;IEC 61000-4-6;IEC 61000-4-8;IEC 61000-4-11

    Performance
    IEC62040-3


                                                                          

    Part NumberDescription
    CN43340TU
    40kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)
    CN43360TU
    60kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)
    CN43380TU
    80kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)

    COMPATIBLE ACCESSORIES

    Part NumberDescription
    CNS01
    SNMP Card