PREMIUM FIRE RESISTANT CABLE

NORDEN FireNor Premium fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning. emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi- intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas. theatres, schools, shopping centers. airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases.

NORDEN FireNor Premium fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning. emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi- intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas. theatres, schools, shopping centers. airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases.

CABLE CONSTRUCTION




Flame Tests Insulation Integrity Smoke Density Corrosive Gases & Halogen Free Test LPCB Stanaderds

IEC 60332-1-2
VDE 0482-332-1-2
EN 60332-1-2
IEC 60332-3-24
VDE 0482-332-3-24
EN 60332-3-24

IEC 60331-23
BS 6387 C, W, Z
Cat,C fire @950°C - 180 min
Cat,W fire and water @ 650°C
-15 +15 min
Cat,Z fire and mechanical
shocks @ 950°C - 15 min.
EN 50200 PH 120
EN 50200(Annex E)

IEC 61034-2
VDE 0482-1034-2
EN 61034-2

IEC 60754-2
VDE 0482-267-2-3
EN 50267-2-3
IEC 60754-1
VDE 0482-267-2-1
EN 50267-2-1

BS 7629-1:2015 (Standard 60) BS 6387:2013 (Category CWZ) BS 5839-1:2013 (Clause 26.2d Standard) EN 50200:2015 (Class PH120)

EN 50200:2015 Annex E

EN 60754-2:2014

EN 60332-3-22:2009 


ELECTRICAL & MECHANICAL CHARACTERISTICS


Properties Value
1.0 mm² 1.5 mm² 2.5 mm² 4.0 mm²

Max. Conductor Resistant @ 20ºC

18.1Ω/km

12.1 Ω/km

7.4 Ω/km

4.61 Ω/km

Min. Insulation Resistant @ 0ºC

200 MΩxkm

Operating Voltage

300/500 V

Test Voltage

2000 V

Temperature Rating(Fixed)

-40ºC to + 70ºC

Temperature Rating(Flexing)

-5ºC to + 60ºC

Min. Bend Radius(Fixed)

6 x D

Min. Bend Radius(Flexing)

15 x D


PHYSICAL INFORMATION


Nom. Cond.
Cross-Sect. mm²
Conductor Size
no./mm
Drain Wire Size no./mm Cable Diameter
mm (±5 %)
Weight Kg/km

2 x 1.0

1/1.12

1/1.12

6.90

77.14

2 x 1.5

1/1.37

1/1.37

7.90

101.39

3 x 1.5

1/1.37

1/1.37

8.20

124.46

4 x 1.5

1/1.37

1/1.37

9.20

156.39

2 x 2.5

1/1.75

1/1.75

9.30

148.19

3 x 2.5

1/1.75

1/1.75

11.0

184.4

4 x 2.5

1/1.75

1/1.75

10.80

229.93

2 x 4.0

1/2.30

1/2.30

10.30

201.56

3 x 4.0

1/2.30

1/2.30

10.40

253.33

4 x 4.0

1/2.30

1/2.30

12.10

315.96

Part Number Description

66-1002XY

Premium Fire Resistant Cable EN 50200 PH120, 2C x 1.0mm²

66-1502XY

Premium Fire Resistant Cable EN 50200 PH120, 2C x 1.5mm²

66-1503XY

Premium Fire Resistant Cable EN 50200 PH120, 3C x 1.5mm²

66-1504XY

Premium Fire Resistant Cable EN 50200 PH120, 4C x 1.5mm²

66-2502XY

Premium Fire Resistant Cable EN 50200 PH120, 2C x 2.5mm²

66-2503XY

Premium Fire Resistant Cable EN 50200 PH120, 3C x 2.5mm²

66-2504XY

Premium Fire Resistant Cable EN 50200 PH120, 4C x 2.5mm²

66-4002XY

Premium Fire Resistant Cable EN 50200 PH120, 2C x 4.0mm

66-4003XY

Premium Fire Resistant Cable EN 50200 PH120, 3C x 4.0mm²

66-4004XY

Premium Fire Resistant Cable EN 50200 PH120, 4C x 4.0mm²

X > BK:Black, RD:Red, WH:White, OR:Orange