NORDEN FireNor PH120 fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centres, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gase
NORDEN FireNor PH120 fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centres, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gase
Flame Tests | Insulation Integrity | Smoke Density | Corrosive Gas & Halogen Free Measurement |
IEC 60332-1-2, VDE 0482-332-1-2 EN 60332-1-2, IEC 60332-3-24, VDE 0482-332-3-24 EN 60332-3-24 | BS 6387: 2013 (C,W,Z) Cat,C fire @ 950°C - 180 min Cat,W fire and water @ 650°C -15 +15 min Cat,Z fire and mechanical shocks @ 950°C - 15 min. IEC 60331-21 (FE180) EN 50200 VDE 0482-200 EN 50200 PH 120 | IEC 61034-2 VDE 0482-1034-2 EN 61034-2
| IEC 60754-2 VDE 0482-267-2-3 EN 50267-2-3 IEC 60754-1 VDE 0482-267-2-1 EN 50267-2-1
|
Properties | Value | ||
1 mm² | 1.5 mm² | 2.5 mm² | |
Max. Conductor Resistant | 18.1Ω/km | 12.1Ω/km | 7.41Ω/ km |
Operating Voltage | 300/500 V | ||
Test Voltage | 2000 V | ||
Temperature Rating(Fixed) | -30ºC to + 70ºC | ||
Temperature Rating(Flexing) | -5ºC to + 50ºC | ||
Min. Bend Radius | 6 x D |
Nom. Cond. Cross-Sect. mm² | Earth Wire Size (mm²) | Cable Diameter mm (±10%) | Weight Kg/km |
2 x 1.0 | 0.5 | 6.00 | 65 |
2 x 1.5 | 0.5 | 7.00 | 79 |
2 x 2.5 | 0.5 | 8.40 | 113 |
3 x 2.5 | 0.5 | 9.10 | 153 |
Part Number | Description |
6Q-1002XY | Fire Resistant Signal Control Cable 2C x 1.0mm² |
6Q-1502XY | Fire Resistant Signal Control Cable 2C x 1.5mm² |
6Q-2502XY | Fire Resistant Signal Control Cable 2C x 2.5mm² |
6Q-2503XY | Fire Resistant Signal Control Cable 3C x 2.5mm² |
6Q-1S02XY | Fire Resistant Signal Control Cable 2C x 1.0 mm² |
6Q-2S02XY | Fire Resistant Signal Control Cable 2C x 1.5mm² |
6Q-4S02XY | Fire Resistant Signal Control Cable 2C x 2.5mm² |
6Q-4S03XY | Fire Resistant Signal Control Cable 3C x 2.5mm² |
X (Colour code) > RD : Red
Y (Packing Length ) > 1: 100mtr, 2:500mtr