Category 7 S/FTP 4 Pair Cable

Category 7 S/FTP 4 Pair Cable

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR. It supports all Ethernet applications up to 1000 Base-T and CATV applications up to 862 Mhz.

Norden Category 7 S/FTP cables exceed Category 7/ Class F specification maximizing the user’s return on investment, by extending the life of the system. It is tested to 600 MHz frequency range and designed to support 10 Gigabyte applications. The cable is of a 4 pair S/FTP construction with individual foiled pair and an overall braid offering superior performance in terms of ACR. It supports all Ethernet applications up to 1000 Base-T and CATV applications up to 862 Mhz.

COMPLIANCE

IEEE 802.3an :2006 (10GBASE-T)
ANSI/TIA-568-C.2:2009 Category 6A
ISO/IEC-11801, 2nd Edition Class EA
IEC 61156-5:2002 Category 6A
LSZH: IEC 60332-1, IEC 60754, IEC 61034

PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Bare Copper

Conductor Size

23 AWG

Normal Conductor Diameter

0.58±0.005 mm

Conductor Construction

Solid

Insulation Material

SFS PE

Insulation O.D.

1.35 mm nom.

Conductor Unit Identification

Solid/Stripe

Colour code

Per TIA/EIA 568-B

Ind. Shield Material

Aluminium/Polyester Foil

Ind. Shield Design

100 % Coverage

Conductor Unit Lay-Up

Pairs

Overall Braid Shield Material

Tinned Copper 0.10 mm

Braid Coverage

More than 40 %

Drain-Wire 

Optional

Outer Jacket Material

LSZH/PVC

Outer Jacket Thickness & Ex. Diameter

0.55±0.05 mm, 7.9±0.5 mm

Rip Cord

Yes

Total Number of Wires

8

Outer Jacket Colour

Per Requirement

Marking

Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Impedance

100 Ω

Max. DC Resistance

73 Ω/km @ 20 °C

Max. Resistance Unbalance

2 %

Capacitance Unbalance

1.2 pF/m max

Velocity of Propagation

78 % nom.

Propagation Delay Skew

25 ns/100m max.

Dielectric Strength

1.5 kV/minute

Dielectric Strength to Shield

1.5 kV/minute

Min. Insulation Resistance

5 GΩ•km

Coupling Attenuation

85 db min @ 30-100 MHz 85-20log (f/100) @100-600 MHz

Max. Tensile Strength - Short Term

130 N

Min. Bend Radius

60 mm

Operating Temperature Range

-35 °C +65 °C

TRANSMISSION PERFORMANCE

Cat7. Screened Horiontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ACR
dB
ELFEXT
dB
PS.ACRF
dB

1

2.0

80.0

77.0

20.0

78.0

79.0

76.0

4

3.7

80.0

77.0

23.0

76.3

78.8

75.8

10

5.7

80.0

77.0

25.0

74.3

76.4

73.4

20

7.4

80.0

77.0

25.0

72.6

73.3

70.3

31.25

10.0

78.8

75.8

23.8

68.8

70.1

67.1

100

18.8

72.4

69.4

20.1

53.6

65.0

62.0

150

22.5

69.6

66.6

18.8

47.1

63.7

60.7

200

26.5

67.9

64.9

18.0

41.4

62.2

59.2

250

29.0

66.5

63.5

17.3

37.5

60.8

57.8

300

33.6

65.3

62.3

16.4

31.7

58.6

55.6

400

38.6

64.0

61.0

16.4

25.4

55.9

52.9

500

44.9

62.3

59.3

16.4

17.4

53.4

51.4

600

48.7

60.8

57.8

16.4

12.1

50.1

47.1

*Supplied cables meets Cat. 7 min. transmission requirements as per IEC 61156-5 Ed. 2

Part Number Description Standard Length

115-10002504X

Category 7 S/FTP 4 Pair Cable LSZH

305 mtr

X:BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow),Roll Length : 2 (500 mtr / roll)