Norden Category 6 S/FTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications.Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to S/FTP (Shielded Twisted Pair) cabling systems. Cat 6 S/FTP armoured Cable Consists of PE Insulated 23AWG Solid Bare Annealed Copper Conductors, twisted 4 pair stranded, ECCS tape Armour, PVC Inner sheath and PE (UV Stabilized) Outer sheath.
Norden Category 6 S/FTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to S/FTP (Shielded Twisted Pair) cabling systems. Cat 6 S/FTP armoured Cable Consists of PE Insulated 23AWG Solid Bare Annealed Copper Conductors, twisted 4 pair stranded, ECCS tape Armour, PVC Inner sheath and PE (UV Stabilized) Outer sheath.
COMPLIANCEIEEE 802.3an :2006 (10GBASE-T) ISO/IEC-11801, 2nd Edition Class E IEC 61156-5:2002 Category 6
|
Conductor Material |
Solid Bare Copper |
Conductor Size |
23 AWG |
Conductor Construction |
Solid |
Insulation Material |
Polyethylene |
Insulation O.D |
<=1.35mm |
Conductor Unit Identification |
Solid/Stripe |
Colour Code |
Per TIA/EIA 568-B |
Conductor Unit Lay-Up |
Pairs |
Total Number Of Wires |
8 |
Individual Shield Material |
100% Mylar Tape (AL/PET) |
Overall Braiding |
40% Tinned Copper |
Inner Jacket Material |
PVC |
Armour |
? 0.125mm |
Outer Jacket Material |
LDPE |
Outer Cable Diameter |
12.6±1.5 mm |
Outer Jacket Colour |
Black |
Conductor Resistance @20°C |
Max. 93.8 ?/KM |
Conductor Resistance Unbalance |
Max. 5 % |
Mutual Capacitance @1KHZ |
Max. 56 nF/KM |
Insulation Resistance |
min. 5000 M?.km |
High Voltage |
2.5 Kv DC/1 min |
Capacitance Earth Unbalance |
Max. 3300 pF/km |
Propagation Delay @ 1, 10, 100 &250 MHz |
Max. 570, 545,538 & 536ns/100 m |
Propagation DeLay Skew 1 – 250 MHz |
Max. 40 ns/100 m |
Characteristic Impedance (1-250 MHz) |
100 ± 15? |
Bending Radius |
15 x Diameter(min.) |
Pulling Force |
11.5 kgs(max.) |
Temperature Range |
-20°C up to +60°C |
Electrical Characteristics meet or exceed 70 Meter TIA Cat 6 Channel Spec.
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PSELFEXT dB |
1 | 2.1 | 65.0 | 62.0 | 19.0 | 63.3 | 60.3 |
4 | 4.0 | 63.0 | 60.5 | 19.0 | 51.2 | 48.2 |
8 | 5.7 | 58.2 | 55.6 | 19.0 | 45.2 | 42.2 |
10 | 6.3 | 56.6 | 54.0 | 19.0 | 43.3 | 40.3 |
16 | 8.0 | 53.2 | 50.6 | 18.0 | 39.2 | 36.2 |
20 | 9.0 | 51.6 | 49.0 | 17.5 | 37.2 | 34.2 |
25 | 10.1 | 50.0 | 47.3 | 17.0 | 35.3 | 32.3 |
31.25 | 11.4 | 48.4 | 45.7 | 16.5 | 33.4 | 30.4 |
62.5 | 16.5 | 43.4 | 40.6 | 14.0 | 27.3 | 24.3 |
100 | 21.3 | 39.9 | 37.1 | 12.0 | 23.3 | 20.3 |
200 | 31.5 | 34.8 | 31.9 | 9.8 | 17.2 | 14.2 |
250 | 35.9 | 33.1 | 30.2 | 8.0 | 15.3 | 12.3 |
Part Number | Description | Standard Length |
113-20813504X |
Cat 6 S/FTP Double jacket Steel Tape Armored External Cable PVC/PE |
305 mtr |
X: BK(Black)