MTP / MPO RUGGEDIZED TRUNK CABLE

Norden MTP/MPO ruggedized Trunk cables provide an efficient way to install a large number of cables quickly. Ruggedized armoured Trunk cables are constructed with a stainless-steel tube over a standard patch cord with an outer jacket. The flexible metal tube limits the bending radius, preventing the optical fibre from breaking. This ensures a safe and durable optical fibre network system It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance. MTP Trunk Cables are factory pre-terminated and available with OM3, OM4, & SM assemblies.

Norden MTP/MPO ruggedized Trunk cables provide an efficient way to install a large number of cables quickly. Ruggedized armoured Trunk cables are constructed with a stainless-steel tube over a standard patch cord with an outer jacket. The flexible metal tube limits the bending radius, preventing the optical fibre from breaking. This ensures a safe and durable optical fibre network system It also provides high flexibility on unplugging and re-use. It is especially suitable for the areas that require rapid deployment of high-density backbone cabling in data centers, and high fibre environments for high performance. MTP Trunk Cables are factory pre-terminated and available with OM3, OM4, & SM assemblies. 

STANDARDS

  • EIA/TIA, Telecocordia GR-326-CORE Standards
  • TIA 605-4 (FOCIS 5)
  • IEC61754-7 


FEATURES

  • Easy to deploy - Factory-terminated systems can save installation and network reconfiguration time.
  • Reliability - use high-standard components to ensure product quality.
  • Factory terminated and tested
  • Allow easy migration from 10GbE to 40GbE or 100GbE
  • Ideal for 400G High-Speed Network connection 


MECHANICAL & ENVIRONMENTAL CHARACTERISTICS


Fibre Mode

Single-mode:OS2 9/125µm

Multimode: OM3/OM4/OM5 50/125µm

ConnectorMTP/MPO 
PolarityType A, Type B, Type C
Peripheral Strength MemberKevlar Yarn
Central Strength Member
FRP (36F to 144F)
ArmouringStainless steel
LengthStandard & Custom Lengths 
Cable JacketPVC, LSZH, OFNP & OFNR
Operating Temperature-20°C ~ 70°C
Storage Temperature -20°C ~ 70°C


TRUNK CABLE PHYSICAL SPECIFICATION


Fibre CountCable DiameterTensile Strength(N)Max Crush Resistance (N/100mm)Minimum Bend Radius (mm)


LongShortLongShortLong Short 
83.0
80150500200020D10D
123.0
80150500
2000
20D
10D
244.280150500
2000
20D
10D
369.55001200500
2000
20D
10D
489.5500
1200
500
2000
20D
10D
7212.0500
1200
500
2000
20D
10D
9613.5500
1200
500
2000
20D
10D
14418.0500
1200
500
2000
20D
10D


MTP / MPO TERMINATION


Type Single-mode (APC polish) Single-mode (PC polish) Multi– mode (PC polish)
Fibre Count12,24,48,72,144 12,24,48,72,144 12,24,48,72,144
Fibre Type
G652D, G657A1, G657A2
G652D, G657A1, G657A2
62.5/125, OM2, OM3, OM4
Maximum Insertion Loss Ultra-Low Loss Standard Ultra-Low Loss
Standard Ultra-Low Loss
Standard

≤0.35 dB 0.25 dB Typical ≤0.70 dB 0.5 dB Typical ≤0.35 dB 0.25 dB Typical ≤0.70 dB 0.5 dB Typical ≤0.35 dB 0.2 dB Typical ≤0.7 dB 0.35 dB Typical
Return Loss ≥60 dB ≥50 dB ≥30 dB
Durability
≥200 times
≥200 times
≥200 times
Test Wavelength
1310 nm / 1550 nm
1310 nm / 1550 nm
850 nm / 1300 nm