Distribution Tight Buffer Armoured Fibre Optic Cable

Distribution Tight Buffer Armoured Fibre Optic Cable

These cables are used for external distribution cables due to ease of their termination and connection.The installer can recognize saving from lower cost of termination of Tight buffer cables. They have high moisture resistance and can be routed across multiple bends.Each fibre is mechanically reinforced with two successive sheaths of 400μm and 900μm which enables direct termination of connectors. Excellent strip force stability, fibre geometrical dimension and transmission performance meets the customer demand. Available in PE,PVC,Plenum outer sheath and tight buffer: 900μm, 600μm. The cable is specially designed for interconnection and equipment connection.    

These cables are used for external distribution cables due to ease of their termination and connection.The installer can recognize saving from lower cost of termination of Tight buffer cables. They have high moisture resistance and can be routed across multiple bends.Each fibre is mechanically reinforced with two successive sheaths of 400μm and 900μm which enables direct termination of connectors. Excellent strip force stability, fibre geometrical dimension and transmission performance meets the customer demand. Available in PE,PVC,Plenum outer sheath and tight buffer: 900μm, 600μm. The cable is specially designed for interconnection and equipment connection.    

COMPLIANCE

ITU-T G652.B OS1
ITU-T G652.D/G655/G657.A1/G657.A2 OS2
ITU-T G651.1 OM1 OM2 OM3 OM4
IEC60793-2-10 type A1a.1/A1b OM1/OM2
IEC60793-2-10 type A1a.2 OM3
IEC60793-2-10 type A1a.3 OM4
ISO/IEC 11801 , ISO/IEC 24702
ANSI/TIA/EIA 568C.3
ROHS compliant Directive 2002/95/EC
LSZH: IEC 60332-1, IEC 60754, IEC 61034

MECHANICAL & ENVIRONMENTAL CHARACTERISTICS

Characteristics Short Term Long Term

Max. Tensile Load

1500 N

600 N

Max. Crush Load

1000 N/100 mm

200 N/100 mm

Operating Temp.

-20 °C to +60 °C

Storage Temp.

-40 °C to +85 °C

Sheath Material

Standard: PE Optional: LSZH, PVC or Other

Part Number Fibre Count Outer Diameter
(mm)
Loose Tube Diameter
(mm)
Cable Weight
(kg/km)
Bend Radius
Short
(mm)
Long
(mm)

3125-31002FXX CL

2

8.5

0.9

70.0

20D

10D

3125-31004FXX CL

4

10.0

0.9

76.0

20D

10D

3125-31006FXX CL

6

10.0

0.9

76.0

20D

10D

3125-31008FXX CL

8

10.5

0.9

85.0

20D

10D

3125-31012FXX CL

12

11.3

0.9

90.0

20D

10D

3125-31016FXX CL

16

12.0

0.9

95.0

20D

10D

3125-31018FXX CL

18

12.5

0.9

100.0

20D

10D

3125-31024FXX CL

24

13.0

0.9

100.0

20D

10D