Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electromagnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien crosstalk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Crosstalk performance.
Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electromagnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien crosstalk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Crosstalk performance.
Product Sequense | Premium |
Product Type | Twisted Pair Cable |
Conductor Material | Solid Bare Copper |
Conductor Size | 23 AWG |
Conductor Construction | 1/0.57 ( ± 0.01 mm) |
Insulation Material | PE |
Insulation Thickness | 0.26 mm |
Insulation Diameter | 1.15 ± 0.08 mm |
Separator | PE Cross |
Wrapping Tape Overlap | Polyester Tape ( ≥ 25% ) |
Drain Wire | Solid Tinned Copper |
Drain Wire Size | 1/0.40 |
Overall Shield | Aluminium / Polyester (≥25% ) |
Outer Jacket Material | LSZH |
Outer Jacket Thickness | 0.50 mm |
Outer Jacket Diameter | 7.50 ± 0.30 mm |
Colour Code | Per TIA/EIA 568-B |
Total Number of Wires | 8 |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Frequency Range | 1 - 250 MHz |
Impedance | 100 Ω ±15 |
DC Resistance | 93 Ω/km |
Resistance Unbalance | ≤ 4 % |
Max. DC Loop Resistance | 19.2 Ω/100m |
Min. Insulation Resistance | 5000 MΩ-KM |
Pair to Ground Capacitance Unbalance | ≤ 330 Pf/100m |
Propagation Delay Skew | ≤ 45 ns/100m |
Velocity of Propagation ( NVP ) | 69 % |
Dielectric Strength | DC-1KV/1 Min |
Before Aging Tensile Strength | ≥ 9 Mpa |
Elongation | ≥ 100 % |
After Aging (100 C*24h*7d ) Tensile Strength | ≥ 75 Mpa |
Elongation | ≥ 50 % |
Min. Bend Radius | 8 x OD |
Operating Temperature Range | -20 °C to +75 °C |
TRANSMISSION PERFORMANCE
*Cat. 6 Un-screened Pair Horizontal Cables*
Freq.MHz | Attenuation dB/100m | RL dB | NEXT dB | ELFEXT dB/100m | PSNEXT dB/100m | PSELFEXT dB/100m |
1 | 2.0 | 20.0 | 74.3 | 67.8 | 72.3 | |
4 | 3.8 | 23.0 | 65.3 | 55.8 | 63.3 | 52.8 |
8 | 5.3 | 24.5 | 60.8 | 49.7 | 58.8 | 46.7 |
10 | 6.0 | 25.0 | 59.3 | 47.8 | 57.3 | 44.8 |
16 | 7.6 | 25.0 | 56.2 | 43.7 | 54.2 | 40.7 |
20 | 8.5 | 25.0 | 54.8 | 41.8 | 52.8 | 38.8 |
25 | 9.5 | 24.3 | 53.3 | 39.8 | 51.3 | 36.8 |
31.25 | 10.7 | 23.6 | 51.9 | 37.9 | 49.9 | 34.9 |
62.5 | 15.4 | 21.5 | 47.4 | 31.9 | 45.4 | 28.9 |
100 | 19.8 | 20.1 | 44.3 | 27.8 | 42.3 | 24.8 |
200 | 29.0 | 18.0 | 39.8 | 21.8 | 37.8 | 18.8 |
250 | 32.8 | 17.3 | 38.3 | 19.8 | 36.3 | 16.8 |
*Supplied cables meet Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
Part Number | Description |
113 - 10002204X | Category 6 F/UTP 4 Pair Cable LSZH |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)