CATEGORY 6 F/UTP 4 PAIR CABLE LSZH

Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electromagnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien crosstalk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Crosstalk performance.

Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electromagnetic Compatibility), minimizing radiation, maximizing noise immunity, and providing high alien crosstalk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Crosstalk performance.



PRODUCT CLASSIFICATION

Product Sequense

Premium

Product Type

Twisted Pair Cable


MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Solid Bare Copper

Conductor Size

23 AWG 

Conductor Construction

1/0.57 ( ± 0.01 mm)

Insulation Material

PE

Insulation Thickness

0.26 mm

Insulation Diameter

1.15 ± 0.08 mm

Separator

PE Cross

Wrapping Tape Overlap

Polyester Tape ( ≥ 25% )

Drain Wire

Solid Tinned Copper

Drain Wire Size

1/0.40

Overall Shield

Aluminium / Polyester (≥25% ) 

Outer Jacket Material

LSZH 

Outer Jacket Thickness 

0.50 mm 

Outer Jacket Diameter

7.50 ± 0.30 mm

Colour Code 

Per TIA/EIA 568-B 

Total Number of Wires

8

Outer Jacket Colour

Per Requirement

Marking 

Per Requirement


ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range 

1 - 250 MHz

Impedance

100 Ω ±15

DC Resistance

93 Ω/km

Resistance Unbalance

≤ 4 %

Max. DC Loop Resistance

19.2 Ω/100m

Min. Insulation Resistance

5000 MΩ-KM

Pair to Ground Capacitance Unbalance

≤ 330 Pf/100m

Propagation Delay Skew

≤ 45 ns/100m

Velocity of Propagation ( NVP ) 

69 % 

Dielectric Strength

DC-1KV/1 Min

Before Aging                                           Tensile Strength

≥ 9 Mpa 

                                                                   Elongation

≥ 100 %

After Aging (100 C*24h*7d )                Tensile Strength

≥ 75 Mpa

                                                                  Elongation

≥ 50 %

Min. Bend Radius

8 x OD

Operating Temperature Range

-20 °C to +75 °C


 TRANSMISSION PERFORMANCE

*Cat. 6 Un-screened Pair Horizontal Cables* 

Freq.MHzAttenuation dB/100mRL dB
NEXT dB
ELFEXT dB/100m
PSNEXT dB/100m
PSELFEXT dB/100m
12.0 
20.0
74.3
67.8
72.3 

43.8 
23.0
65.3
55.8
63.3 
52.8
85.3 
24.560.849.7 58.846.7
10 
6.0 
25.0
59.3
47.8
57.3
44.8
16 
7.6 
25.0
56.2
43.7
54.2 
40.7
20
8.5
25.0
54.8
41.8 
52.8 
38.8
259.5 
24.3
53.3
39.8 
51.3 
36.8
31.2510.7 
23.6
51.9
37.9 
49.9 
34.9
62.5
15.4 
21.5
47.4
31.9 
45.4
28.9
100
19.8 
20.1
44.3
27.8 
42.3 
24.8
200
29.0
18.0
39.8
21.8
37.8
18.8
250
32.8 
17.3
38.3
19.8
36.3 
16.8

*Supplied cables meet Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2

Part NumberDescription
113 - 10002204X 
Category 6 F/UTP 4 Pair Cable LSZH

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)