Norden Category 6 U/UTP cables exceed Category 6/Class E specification.It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 U/UTP cables are UL listed CM, CMX, CMR & CMP and standard packing will be 305m easy pull out boxes. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems.
Norden Category 6 U/UTP cables exceed Category 6/Class E specification.It is tested to 250MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications to full 100m. Norden Category 6 U/UTP cables are UL listed CM, CMX, CMR & CMP and standard packing will be 305m easy pull out boxes. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems.
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material |
Bare Copper |
Conductor Size |
0.53 mm, 24 AWG |
Conductor Construction |
Solid |
Insulation Material |
High Density PE |
Insulation Diameter |
0.93±0.05 mm |
Conductor Unit Identification |
Solid/Stripe |
Colour Code |
Per TIA/EIA 568-B |
Total Number of Wires |
8 |
Rip Cord |
Yes |
Seperator |
Yes |
Overall Drain-Wire Material |
N/A |
Outer Jacket |
LSZH Low Smoke Zero Halogen or PVC |
Outer Jacket Thickness & Ex. Diameter |
0.54±0.05 mm, 6.0±0.2 mm |
Outer Jacket Colour |
Per Requirement |
Marking |
Per Requirement |
Frequency Range |
1 - 250 MHz |
Impedance |
100 ±15 Ω |
Coupling Attenuation |
40 dB min @ 30-100 MHz 40-20 Log (f/100) @100-300 MHz |
DC Resistance |
98.3 Ω/km norm. |
Max. Resistance Unbalance |
2.5 % |
Capacitance |
5.6 nF/100m Max |
Capacitance Unbalance |
3.3 pF/m max. |
Propagation Delay Skew |
35 ns/100m max |
Velocity of propagation |
69 % |
Dielectric Strength |
1 KV/minute |
Min. Insulation Resistance |
5 GΩ•km |
Max.Tensile Strength - Short Term |
110 N |
Min. Bend Radius |
54 mm |
Operating Temperature Range |
-10 °C +65 °C |
Cat. 6 Un-screened Pair Horizontal Cables*
Freq. Mhz |
Attenuation dB/100m @ 20°C |
NEXT dB | PSNEXT dB | RL dB | ELFEXT dB | PSELFEXT dB |
1 |
2.0 |
74.3 |
72.3 |
20.0 |
67.8 |
64.8 |
4 |
3.8 |
65.3 |
63.3 |
23.0 |
55.8 |
52.8 |
10 |
6.0 |
59.3 |
57.3 |
25.0 |
47.8 |
44.8 |
20 |
8.5 |
54.8 |
52.8 |
25.0 |
41.8 |
38.8 |
31.25 |
10.7 |
51.9 |
49.9 |
23.6 |
37.9 |
34.9 |
100 |
19.8 |
44.3 |
42.3 |
20.1 |
27.8 |
24.8 |
200 |
29.0 |
39.8 |
37.8 |
18.0 |
21.8 |
18.8 |
250 |
32.8 |
38.3 |
36.3 |
17.3 |
19.8 |
16.8 |
*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
120-11001104X | Category 6 U/UTP 4 Pair 24AWG Cable PVC W/S | 305 mtr |
120-11002104X | Category 6 U/UTP 4 Pair 24AWG Cable LSZH W/S | 305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)
Packing Length: 2 : 500Mtr