E-Glass Strength Central Loose Tube In/Out Fibre Optic Cable

E-GLASS STRENGTH CENTRAL LOOSE TUBE IN/OUT FIBRE OPTIC CABLE

This cable is constructed with FRP Central Strength Member, Central Loose Tube with Jelly Compound which gives water and moisture protection, E-Glass Strength Member and PVC outer Jacket with metric print. E-glass gives better tensile strength and protection.The cable has options of LSZH, PE or Plenum outer jacket as per customer request.The cable has excellent UV-stabilized and water blocking performance for External duct application (PE outer jacket) or Internal/ External application (LSZH outer jacket). By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for External cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).

This cable is constructed with FRP Central Strength Member, Central Loose Tube with Jelly Compound which gives water and moisture protection, E-Glass Strength Member and PVC outer Jacket with metric print. E-glass gives better tensile strength and protection.The cable has options of LSZH, PE or Plenum outer jacket as per customer request.The cable has excellent UV-stabilized and water blocking performance for External duct application (PE outer jacket) or Internal/ External application (LSZH outer jacket). By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for External cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).

COMPLIANCE

ITU-T G652.B OS1
ITU-T G652.D/G655/G657.A1/G657.A2 OS2
ITU-T G651.1 OM1 OM2 OM3 OM4
IEC60793-2-10 type A1a.1/A1b OM1/OM2
IEC60793-2-10 type A1a.2 OM3
IEC60793-2-10 type A1a.3 OM4
ISO/IEC 11801 , ISO/IEC 24702
ANSI/TIA/EIA 568C.3
ROHS compliant Directive 2002/95/EC
LSZH: IEC 60332-1, IEC 60754, IEC 61034

MECHANICAL & ENVIRONMENTAL CHARACTERISTICS

Characteristic Short Term Long Term

Max. Tensile Load

1500 N

600 N

Max. Crush Load

1000 N/100 mm

300 N/100 mm

Operating Temp.

-20 °C to +60 °C

Storage Temp.

-40 °C to +85 °C

Sheath Material

Standard: PVC Optional: LSZH, PE, FR PVC (OFNP/OFNR)

Part Number Fibre Count Outer Diameter
(mm)
Loose Tube Diameter
(mm)
Cable Weight
(kg/km)
Bend Radius
Short
(mm)
Long
(mm)
 3106-11002FXXCL26.02.840.020D10D

3106-11004FXXCL

4

6.0

2.8

40.0

20D

10D

3106-11006FXXCL

6

6.0

2.8

40.0

20D

10D

3106-11008FXXCL

8

6.0

2.8

42.0

20D

10D

3106-11012FXXCL

12

6.0

2.8

44.0

20D

10D

3106-11016FXXCL

16

7.0

3.5

60.0

20D

10D

3106 -11024FXXCL

24

8.0

3.5

65.0

20D

10D