Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Data integrity is one of the most essential network requirements for many corporations especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airport as well as those running critical systems such as military installations and hospitals. U/FTP cabling systems are installed for improved alien cross talk performance.
Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Data integrity is one of the most essential network requirements for many corporations especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airport as well as those running critical systems such as military installations and hospitals. U/FTP cabling systems are installed for improved alien cross talk performance.
Product Sequence | E Series |
Product Type | Twisted Pair Cable |
Conductor Material | Bare Copper |
Conductor Size | 23 AWG |
Conductor Construction | Solid |
Insulation Material | SFS PE |
Insulation O.D. | 1.36±0.05 mm |
Colour Code | Per TIA/EIA 568-B |
In. Shield Material | Aluminium/Polyester Foil |
In. Shield Design: | 100% Coverage |
Conductor Unit Lay-Up: | Pairs |
Total Number of Wires: | 8 |
Outer Jacket | LSOH |
Outer Jacket thickness & Ex. Diameter | 0.55±0.05mm, 7.5±0.5mm |
Rip Cord: | Yes |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Characteristic Impedance: | 100Ω |
Frequency Range | 1-500MHz |
Coupling Attenuation | 55 dB min @ 30-100 MHz 55-20Log(f/100) @100-500 MHz |
Max. DC Resistance | 73 Ω/km@20°C |
Max. Resistance Unbalance | 2 % max. |
Mutual Capacitance | 43 pF/m nom. |
Cap. Unbalance | 1.2 pF/m max |
Velocity of Propagation (NVP) | 78 % nom |
Propagation Delay Skew: | 25 ns/100m max |
Dielectric Strength | 1.5kV/minute |
Min. Insulation Resistance | 5 GΩ•km |
Max. Tensile Strength - Short Term | 130N |
Transfer Impedance | 10 m/m max @ 1-10 MHz 30 m/m max @ 30 MHz |
Freq. MHz | Attenuation dB/100m @ 20ºC | NEXT dB | PSNEXT dB | RL dB | ACR dB | ELFEXT dB | PSELFEXT dB |
1 | 1.7 | 86.3 | 83.3 | 26.0 | 84.6 | 84.0 | 81.0 |
4 | 3.4 | 85.0 | 83.0 | 29.0 | 75.6 | 81.0 | 78.0 |
10 | 5.4 | 77.3 | 74.3 | 31.0 | 71.9 | 76.0 | 73.0 |
20 | 7.6 | 70.0 | 67.0 | 30.0 | 62.4 | 70.0 | 67.0 |
100 | 18.0 | 65.3 | 62.3 | 27.1 | 47.3 | 55.0 | 52.8 |
150 | 23.6 | 62.0 | 59.8 | 26.0 | 38.4 | 53.5 | 51.5 |
200 | 27.4 | 59.0 | 57.2 | 25.0 | 31.6 | 49.0 | 46.0 |
250 | 31.0 | 57.6 | 54.6 | 25.2 | 26.6 | 44.0 | 41.0 |
300 | 34.2 | 55.0 | 52.0 | 24.0 | 20.3 | 39.6 | 36.6 |
400 | 40.0 | 53.0 | 51.8 | 21.8 | 13.0 | 37.0 | 34.0 |
500 | 42.2 | 52.0 | 50.0 | 21.8 | 9.8 | 35.0 | 33.0 |
Part Number | Description | Standard Length |
114-40002304X | Category 6A U/FTP 23 AWG 4 Pair Cable LSOH E Series | 305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)