Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. U/FTP (Foil Twisted Pair) cabling systems are installed for improved Alien Cross talk performance.
Norden Category 6A U/FTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. U/FTP (Foil Twisted Pair) cabling systems are installed for improved Alien Cross talk performance.
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material | Solid-Bare Copper |
Conductor Size | 0.560±0.005 mm , 23 AWG |
Conductor Construction | Solid |
Insulation Material | SES PE |
Insulation O.D. | 1.33±0.05 mm |
Conductor Unit Identification | Solid/Stripe |
Conductor Unit Lay-Up | Pairs |
Total Number of Wires | 8 |
In. Shield Material | Al/Mylar |
In. Shield Design | 100% Coverage |
Drain-Wire | Yes |
Rip cord | Yes |
Outer Jacket Material | LSZH UV Resistant |
Outer Jacket thickness & Ex. Diameter | 0.55±0.05 mm, 6.3±0.4 mm |
Outer Jacket Colour | Black |
Conductor Impedance | 100 ± 15 Ω ( 1- 250 MHz ) 100 ± 22 Ω ( 250 – 500 Mhz ) |
Max. DC Resistance | 9.38 Ω/100m |
Max. DC Conductor Resistance Unbalance | 5.0 % |
Mutual Capacitance | 4.3 nf/100m |
Max. Unbalanced-to-Ground Capacitance | 330 pf/100m |
Dielectric Strength | 1.5 KV/minute |
Delay Skew @ 1-500 Mhz | ≤ 45 ns/100m |
Before Aging Tensile Strength | ≥ 10.0 Mpa |
Before Aging Elongation | ≥ 125 % |
Aging Period (°C × hrs) | 100°C × 24h × 7d |
After Aging Tensile Strength | ≥ 8.0 Mpa |
After Aging Elongation | ≥ 100 % |
Min. Bend Radius | 8 x OD |
Operating Temperature | -20°C to +70°C |
Cat. 6a Un-screened Pair Horizontal Cables*
Freq. MHz | Attenuation dB/100m @ 20°C | NEXT dB | PSNEXT dB | RL dB | ELFEXT dB | PSELFEXT (dB@100m )min | PHASE DELAY ns |
1 | - | 74.3 | 72.3 | 20.0 | 67.8 | 64.8 | 570 |
4 | 3.8 | 65.3 | 63.3 | 23.0 | 55.8 | 52.8 | 552 |
8 | 5.3 | 60.8 | 58.8 | 24.5 | 49.7 | 46.7 | 547 |
10 | 5.9 | 59.3 | 57.3 | 25.0 | 47.8 | 44.8 | 545 |
16 | 7.5 | 56.2 | 54.2 | 25.0 | 43.7 | 40.7 | 543 |
20 | 8.4 | 54.8 | 52.8 | 25.0 | 41.8 | 38.8 | 542 |
25 | 9.4 | 53.3 | 51.3 | 24.3 | 39.8 | 36.8 | 541 |
31.25 | 10.5 | 51.9 | 49.9 | 23.6 | 37.9 | 34.9 | 540 |
62.5 | 15.0 | 47.4 | 45.4 | 21.5 | 31.9 | 28.9 | 539 |
100 | 19.1 | 44.3 | 42.3 | 20.1 | 27.8 | 24.8 | 538 |
200 | 27.6 | 39.8 | 37.8 | 18.0 | 21.8 | 18.8 | 537 |
250 | 31.1 | 38.3 | 36.3 | 17.3 | 19.8 | 16.8 | 536 |
300 | 34.3 | 37.1 | 35.1 | 16.8 | 18.3 | 15.3 | 536 |
400 | 40.1 | 35.3 | 33.3 | 15.9 | 15.8 | 12.8 | 536 |
500 | 45.3 | 33.8 | 31.8 | 15.2 | 13.8 | 10.8 | 536 |
*Supplied cables meets Cat. 6 min. transmission requirements as per IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
114-2000Y304X | Category 6A U/FTP 4 Pair 23 AWG External Cable UV Resistant LSZH | 305 mtr |
X : BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow) , PU ( Purple )