Norden Category 5e F/UTP cables exceed Category 5e / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications upto 100m. Norden Category 5e F/UTP cables standard packing are in 305m easy pull out boxes. F/ UTP (Twisted Pair – overall Foil shield) cabling systemsareinstalledfor improvedAlien Crosstalk performance. By design, Norden cables are manufactured to the highest quality standards, design requirements and materials to ensure that every box provides significant margin over ANSI/ TIA-568.2-D specifications for NEXT, Power Sum NEXT and Insertion Loss across the entire channel.
Norden Category 5e F/UTP cables exceed Category 5e / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications upto 100m. Norden Category 5e F/UTP cables standard packing are in 305m easy pull out boxes. F/ UTP (Twisted Pair – overall Foil shield) cabling systemsareinstalledfor improvedAlien Crosstalk performance. By design, Norden cables are manufactured to the highest quality standards, design requirements and materials to ensure that every box provides significant margin over ANSI/ TIA-568.2-D specifications for NEXT, Power Sum NEXT and Insertion Loss across the entire channel.
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material | Bare Copper |
Conductor Size | 24 AWG |
Conductor Diameter | 0.51 mm |
Conductor Construction | Solid |
Insulation Material | High Density PE |
Insulation O.D. | 1.03 mm nom. |
Conductor Unit Identification | Solid/Stripe |
Colour Code. | Per TIA/EIA 568-B |
Total Number of Wires | 8 |
Screening Material | Aluminium/Polyster foil |
Screening Design | 100 % Coverage |
Conductor Unit Lay-Up | Pairs |
Overall Drain-Wire Material | Tinned Copper 0.10 mm |
Overall Drain-Wire Construction | Solid |
Outer Jacket | LSZH (Low Smoke Zero Halogen) or PVC |
Outer Jacket Thickness & Ex. Diameter | 0.55±0.05 mm, 6.3±0.3 mm |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Frequency Range | 1 - 100 MHz |
Impedance | 100 Ω ±15 |
Coupling Attenuation | 40 dB min @ 30-100 MHz |
Max. Dc Resistance | 93 Ω/km @ 20 °C |
Max. Resistance Unbalance | 5 % |
Capacitance | 5.6 nF/100m max. |
Capacitance Unbalance | 3.3 pF/m max. |
Velocity Of Propagation | 69 % |
Propagation Delay Skew | 25 ns/100m max. |
Dielectric Strength | 1 KV/minute |
Min. Insulation Resistance | 5 GΩ•km |
Max. Tensile Strength - Short Term | 110 N |
Min. Bend Radius | 40 mm |
Operating Temperature Range | -20 °C +65 °C |
Cat. 5e Screened Pair Horizontal Cables*
Freq. MHz |
Attenuation dB/100m @ 20°C |
NEXT dB |
PSNEXT dB |
RL dB |
ELFEXT dB |
PSELFEXT dB |
1.0 | 2.0 | 73.3 | 71.3 | 24.8 | 80.0 | 78.0 |
4.0 | 3.8 | 69.3 | 67.3 | 27.0 | 67.8 | 65.0 |
10.0 | 6.0 | 59.3 | 57.3 | 29.0 | 59.0 | 57.0 |
20.0 | 9.20 | 53.8 | 51.8 | 29.0 | 53.0 | 51.0 |
31.25 | 11.6 | 50.9 | 48.9 | 28.1 | 49.0 | 47.0 |
62.5 | 16.8 | 46.4 | 44.4 | 26.5 | 43.0 | 41.0 |
100.0 | 21.7 | 43.3 | 41.2 | 24.1 | 38.8 | 36.8 |
*Supplied cables meets Cat. 5e min. transmission requirements of IEC 61156-5 Ed. 2
Part Number | Description | Standard Length |
112-11001204X | Category 5e F/UTP 4 Pair Cable PVC | 305 mtr |
112-11002204X | Category 5e F/UTP 4 Pair Cable LSZH | 305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)