Norden Category 8 S/FTP patch cords are manufactured using stranded bare copper and feature cable strain relief boots with a plug latch protection cap. This patch cord is mainly used in Telephone and other communication circuits such as voice, data, and audio for on- premises customer systems. Each patch cord is tested with Fluke tester and individual cover included with the report. Norden Category 8 Patch cord is tested for transmission frequencies of up to 2000 MHz.
Norden Category 8 S/FTP patch cords are manufactured using stranded bare copper and feature cable strain relief boots with a plug latch protection cap. This patch cord is mainly used in Telephone and other communication circuits such as voice, data, and audio for on- premises customer systems. Each patch cord is tested with Fluke tester and individual cover included with the report. Norden Category 8 Patch cord is tested for transmission frequencies of up to 2000 MHz.
ANSI/TIA-568.2-D
ISO / IEC TR 11801-9901 : 2014 Category 8.
IEEE 802.3af PoE, IEEE 802.3bt Type 4 and IEEE 802.3at PoE+ applications.
Basic Cable Conductor | Stranded Bare Copper |
Conductor Size | 26 AWG 7x0.156(±0.003mm) |
Wire Insulation | SFS PE |
Insulation Diameter | 1.06±0.02mm |
Individual Pair Shield | Polyester/Aluminium Foil |
Overall Shield | Tinned Copper, Braid |
Braid Coverage | Min 30% Coverage |
Outer Jacket Thickness | 0.55mm |
Outer Diameter | 5.9±0.2mm |
Number Of Insulated Conductors | 8 |
Colour Code of Pairs | Blue x White, Orange x White, Green x White, Brown x White |
Jacket And Boot Colour | Per Requirement |
Standard Surface Marking | Includes Norden P/N, Cable Description. |
Characteristic Impedance | 100±15 Ohms |
Transfer Impedance | Max. 100 mΩ/m at 100MHz |
DC Resistance | Max. 14.0 Ω/100m |
DC Resistance Unbalance | Max. 2% Within a pair at 20°C |
DC Resistance Unbalance Pair-Pair | Max. 5% at 20°C |
Dielectric Strength | 1kV DC/0.7kV AC for 1min. or 2.5kV DC/1.7kV AC for 2s |
Insulation Resistance | 5000MΩ/km |
Capacitance Unbalance Pair-Ground | Max. 36pF/30m, 1kHz at 20℃ |
Coupling Attenuation | Min. 35dB at 1GHz |
Phase Delay | Max. 536ns/100m at 2000MHz |
Delay Skew | Max. 45ns/100m, from 4 to 2000MHz |
Nominal Velocity Propagation | 76.5% at 100MHz |
PoE | 60Vdc, 4PPoE 100W, IEEE802.3bt Type 4 |
Voltage Rating | 300V |
Bend Radius | 4 x O.D |
Installation Temperature | 0°C to +50°C |
Storage Temperature | -40°C to +60°C |
Operating Temperature | -20°C to +60°C |
Pulling Tension | Max. 100N |
ELECTRICAL PERFORMANCE DATA
Frequency(Mhz) | Return loss Min. dB | Insertion loss
Max. dB | NEXT
Min. dB | PSNEXT
Min. dB
| ACRF
Min. dB | PSACRF
Min. dB | TCL Min.dB |
1 | 19.4 | 0.8 | 77.0 | 74.0 | 78.0 | 75.0 | 40.0 |
4 | 23.0 | 1.7 | 66.3 | 63.3 | 67.0 | 64.0 | 40.0 |
100 | 22.2
| 8.3 | 45.3
| 42.3 | 39.0
| 36.0 | 20.0 |
250 | 19.4 | 13.4 | 54 | 43.3 | 31.0 | 28.0 | 14.0 |
500 | 17.3 | 19.2 | 34.8 | 39.2 | 25.0 | 22.0 | 9.5 |
600 | 16.8 | 21.2 | 33.6 | 30.6 | 23.4 | 20.4 | 8.3 |
1000 | 15.2 | 27.9 | 30.3 | 27.3 | 19.0 | 16.0 | 7.0 |
1500 | 14.0 | 34.7 | 27.7 | 24.7 | 15.5 | 12.5 | 7.0 |
2000 | 13.1 | 40.7 | 25.8 | 22.8 | 13.0 | 10.0 | 7.0 |
Part Number | Description | Length |
NC32-T6501X | Category 8 S/FTP Patch Cord UV resistant LSZH 01m, AWG 26 | 1m |
NC32-T6502X | Category 8 S/FTP Patch Cord UV resistant LSZH 02m, AWG 26 | 2m |
NC32-T6503X | Category 8 S/FTP Patch Cord UV resistant LSZH 03m, AWG 26 | 3m |
NC32-T6505X | Category 8 S/FTP Patch Cord UV resistant LSZH 05m, AWG 26 | 5m |
NC32-T2501X | Category 8 S/FTP Patch Cord LSZH 01m, AWG 26 | 1m |
NC32-T2502X | Category 8 S/FTP Patch Cord LSZH 02m, AWG 26 | 2m |
NC32-T2503X | Category 8 S/FTP Patch Cord LSZH 03m, AWG 26 | 3m |
NC32-T2505X | Category 8 S/FTP Patch Cord LSZH 05m, AWG 26 | 5m |
NC32-T1501X | Category 8 S/FTP Patch Cord PVC 01m, AWG 26 | 1m |
NC32-T1502X | Category 8 S/FTP Patch Cord PVC 02m, AWG 26 | 2m |
NC32-T1503X | Category 8 S/FTP Patch Cord PVC 03m, AWG 26 | 3m |
NC32-T1505X | Category 8 S/FTP Patch Cord PVC 05m, AWG 26 | 5m |