Category 7A S/FTP 4 Pair Cable

Category 7A S/FTP 4 Pair Cable

Norden Category 7A S/FTP cables exceed Category 7A/Class FA specification, maximizing the user’s return on investment, by extending the life of the system. It is tested to 1000MHz frequency range and designed to support Broadband CATV and other 10 Gigabyte applications. Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. S/FTP (Foil Twisted Pair - Shielded) cabling systems are installed to protect data from potentially corrupting electromagnetic interference (EMI) and improved Alien Cross talk performance.  

Norden Category 7A S/FTP cables exceed Category 7A/Class FA specification, maximizing the user’s return on investment, by extending the life of the system. It is tested to 1000MHz frequency range and designed to support Broadband CATV and other 10 Gigabyte applications. Data integrity is one of the most essential network requirements for many corporations, especially those located in environments that are prone to noise and electromagnetic interference such as industrial facilities and airports, as well as those running critical systems such as military installations and hospitals. S/FTP (Foil Twisted Pair - Shielded) cabling systems are installed to protect data from potentially corrupting electromagnetic interference (EMI) and improved Alien Cross talk performance.  

COMPLIANCE

IEEE 802.3an :2006 (10GBASE-T)
ANSI/TIA-568-C.2:2009 Category 6A
ISO/IEC-11801, 2nd Edition Class EA
IEC 61156-5:2002 Category 6A
LSZH: IEC 60332-1, IEC 60754, IEC 61034

PRODUCT CLASSIFICATION

Product Sequence Premium
Product Type Twisted Pair Cable

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Bare Copper

Conductor Size

23 AWG

Normal Conductor Diameter

0.57±0.005 mm

Conductor Construction

Solid

Insulation Material

SFS PE

Insulation O.D.

1.35 mm nom.

Conductor Unit Identification

Solid/Stripe

Colour Code

Per TIA/EIA 568-B

Ind. Shield Material

Aluminium/Polyester Foil

Ind. Shield Design

Aluminium Face Outwards

Conductor Unit Lay-Up

Pairs

Drain Wire

N/A

Overall Shield Design

Braid

Overall Shield Material

Tinned Copper 0.10 mm

Braid Coverage

More than 40 %.

Total Number of Wires

8

Rip Cord

yes

Outer Jacket Material

LSZH Low Smoke Zero Halogen or PVC

Outer Jacket Thickness & Ex. Diameter

0.55±0.05 mm, 7.9±0.5 mm

Outer Jacket Colour

Per Requirement

Marking

Per Requirement

ELECTRICAL & MECHANICAL CHARACTERISTICS

Frequency Range

1 - 1000 MHz

Impedance

100 Ω

Max. DC Resistance

73 Ω/km @ 20 °C

Max. Resistance Unbalance

2 %

Capacitance

44 pF/m

Capacitance Unbalance

1.2 pF/m max.

Velocity of Propagation

78 % nom.

Propagation Delay Skew

25 ns/100m max.

Dielectric Strength

1.5 kV/minute

Dielectric Strength to Shield

1.5 kV/minute

Min. Insulation Resistance

5 GΩ•km

Coupling Attenuation

85 db min @ 30-100 MHz 85-20 log (f/100) @100-1000 MHz

Max. Tensile Strength - Short Term

130 N

Min. Bend Radius

60 mm

Operating Temperature Range

+80 °C to -20 °C

TRANSMISSION PERFORMANCE

Cat.7A Screened Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ACR
dB
ELFEXT
dB
PS.ACRF
dB

1

2.0

100.0

97.0

27.0

98.0

91.0

88.0

4

3.4

99.8

96.8

30.0

96.4

91.0

88.0

10

5.3

99.3

96.3

30.0

94.0

90.4

87.4

20

7.3

99.1

95.0

30.0

91.8

88.6

85.6

31.25

9.1

99.0

94.5

29.8

89.9

87.3

84.3

100

17.1

98.7

93.6

26.0

81.5

84.4

81.5

150

21.0

96.5

93.0

26.0

75.5

82.5

79.3

200

25.0

95.2

92.2

26.0

70.2

80.0

77.0

250

28.7

94.8

92.8

25.6

66.1

77.0

74.0

300

31.0

93.3

91.3

25.6

62.3

74.8

71.8

400

33.4

91.9

90.0

25.0

58.5

69.0

67.2

500

38.0

89.9

88.9

25.0

51.9

66.6

64.6

600

43.1

86.1

86.0

25.0

43.0

62.0

60.0

1000

57.5

82.0

81.0

23.0

24.5

48.1

45.1

*Supplied cables meets Cat. 7a min. transmission requirements as per IEC 61156-5 Ed. 2

Part Number Description Standard Length

116-10002504X

Category 7a S/FTP 4 Pair Cable LSZH

305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)