Category 6a U/UTP 23 AWG 4 pair cable LSOH

Category 6a U/UTP 23 AWG 4 pair cable LSOH

Norden Category 6A U/UTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Norden Category 6A UTP cables are CPR Compliance to B2ca-s1a,d1,a1.Extremely high pair-balance providing excellent EMC (ElectroMagnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems.

Norden Category 6A U/UTP cables exceed Category 6A/Class EA specification. It is tested to 500MHz frequency range and designed to support 10 Gigabyte applications to full 100m. Norden Category 6A UTP cables are CPR Compliance to B2ca-s1a,d1,a1.Extremely high pair-balance providing excellent EMC (ElectroMagnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to U/UTP (Unshielded Twisted Pair) cabling systems.




PRODUCT CLASSIFICATION


Product Sequence Euro Class
Product Type Twisted Pair Cable


MATERIAL CONSTRUCTION & DESIGN


Conductor Material Bare Copper
Conductor Size 0.57 mm, 23 AWG
Conductor Construction Solid
Insulation Material High Density PE
Insulation O.D. 1.03 mm nom.
Colour Code Per TIA/EIA 568-B
Conductor Unit Lay-Up Pairs
Total Number of Wires 8
Outer Jacket Material LSOH
Outer jacket thickness & Ex. Diameter 0.65±0.05 mm, 6.9±0.4 mm
Outer Jacket Colour Per requirement
Rip Cord Yes


ELECTRICAL & MECHANICAL CHARACTERISTICS


Pulling Force 110 N/mm² max.
Delay Skew 25 ns/100m max.
Characteristic Impedance 100±6 Ω @ 1-500 MHz
DC Resistance 72 Ω/Km max.
Resistance Unbalance 2 % max.
Capacitance 45 pF/m nom.
Cap. Unbalance (Wire to Ground) 1500 pF/Km max.
Velocity of Propagation (NVP) 67 %
Insulation Resistance 5000 MΩ•Km min.
Transfer Impedance N/A
Short Term Bend Radius 8 x OD mm
Long Term Bend Radius 4 x OD mm
Operating Temperature Range -20°C to +60°C


TRANSMISSION PERFORMANCE

Cat. 6 Un-screened Pair Horizontal Cables*
Freq.
MHz
Attenuation
dB/100m @ 20ºC
NEXT
dB
PSNEXT
dB
RL
dB
ACR
dB
ELFEXT
dB
PSELFEXT
dB
1 1.7 86.3 83.3 26.0 84.6 84.0 80.0
4 3.4 85.0 83.0 29.0 75.6 81.0 78.0
10 5.4 77.3 74.3 31.0 71.9 76.0 73.0
20 7.6 70.0 67.0 30.0 62.4 70.0 67.0
100 18.0 65.3 62.3 27.1 47.3 55.0 52.8
150 23.6 62.0 59.8 26.0 38.4 53.5 51.5
200 27.4 59.0 57.2 25.0 31.6 49.0 46.0
250 31.0 57.6 54.6 25.2 26.6 44.0 41.0
300 34.2 55.0 52.0 24.0 20.3 39.6 36.6
400 40.0 53.0 51.8 21.8 13.0 37.0 34.0
500 42.2 52.0 50.0 21.8 9.8 35.0 33.0

Part Number Description Standard Length
114-10009104X Category 6A U/UTP 23 AWG 4 Pair Cable LSOH 305 mtr

 

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)

 

Downloads

Certificate of Constancy of Performance 139.19 KB DOWNLOAD
Declaration of Performance 578.56 KB DOWNLOAD
Certificate of Conformance 180.88 KB DOWNLOAD