Norden Category 6A F/UTP Galvanized Iron Armoured cables exceed Category 6A/ Class EA Specification. It is tested to 250 MHz frequency range and designed to support 10 Gigabyte and External applications.Extremely high pair-balance providing excellent EMC(Electro Magnetic Compatibility),minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/UTP cabling systems. F/UTP (Twisted Pair - overall Foil shield)cabling systems are installed for improved Alien Cross talk performance.
Norden Category 6A F/UTP Galvanized Iron Armoured cables exceed
Category 6A/ Class EA Specification. It is tested to 250 MHz
frequency range and designed to support 10 Gigabyte and External
applications.Extremely high pair-balance providing excellent
EMC(Electro Magnetic Compatibility),minimizing radiation,
maximizing noise immunity and providing high alien cross talk
performance to F/UTP cabling systems. F/UTP (Twisted Pair -
overall Foil shield)cabling systems are installed for improved Alien
Cross talk performance.
Conductor Material | Solid Bare Electrolytic Grade Copper |
Conductor Size | 0.57 mm, 23 AWG |
Conductor Construction | Solid |
Insulation Material | Polyolefin |
Conductor Unit Identification | Solid/Stripe |
Colour Code | Per TIA/EIA 568-B |
Overall Shield Design | 100 % Coverage |
Overall Foil Shield | Yes |
Overall Shield Material | Aluminium Foil |
Overall Drain-Wire Material | Annealed Tinned Copper |
Overall Drain-Wire Construction | Solid |
Total number of Wires | 8 |
Inner Sheath Material | LDPE |
Armoured Material | Galvanized Iron Armour |
Armouring Thickness | 0.6mm |
Outer Jacket Material | HDPE |
Outer Jacket Diameter | 9.80 ± 0.50 mm |
Rip Cord | Yes |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Frequency Range | 1 - 500 MHz |
Impedance | 100 ± 15% Ohms |
DC Resistance | Max. 93.8 @20°c Ohm/km |
Max. Resistance Unbalance | Max. 5 % |
Capacitance | Max. 5.6 nf/100 mtr |
Capacitance Unbalance | Max. 330 pf/100 mtr |
Velocity of Propagation | 69 % |
Propagation Delay Skew | 45 ns/100 mtr |
Dielectric Strength | 1.5 KV/minute |
Dielectric Strength to Shield | 1.5 KV/minute |
Min. Insulation Resistance | 5 GΩkm |
Max. Tensile Strength - Short Term | 130 N |
Min. Bend Radius | 50 mm |
Operating Temperature Range | - 15 °C to + 70 °C |
Electrical Characteristics meet or exceed 70 Meter TIA Cat 6A Channel Spec.
Freq. MHz | ATT (dB/100m) max | NEXT (dB) min. | PS NEXT (dB) min. | ACRF (dB@100m) min | PS. ACRF (dB@100m) min | Return Loss (dB/100 m) |
1 | 2.3 | 65 | 62 | 63.3 | 60.3 | 19 |
4 | 4.2 | 63 | 60.5 | 51.2 | 48.2 | 19 |
8 | 5.8 | 58.2 | 55.6 | 45.2 | 42.2 | 19 |
10 | 6.5 | 56.6 | 54 | 43.3 | 40.3 | 19 |
16 | 8.2 | 53.2 | 50.6 | 39.2 | 36.2 | 18 |
20 | 9.2 | 51.6 | 49 | 37.2 | 34.2 | 17.5 |
25 | 10.2 | 50 | 47.3 | 35.3 | 32.3 | 17 |
100 | 20.9 | 39.9 | 37.1 | 23.3 | 20.3 | 12 |
200 | 30.1 | 34.8 | 31.9 | 17.2 | 14.2 | 9 |
250 | 33.9 | 33.1 | 30.2 | 15.3 | 12.3 | 8 |
300 | 37.4 | 31.7 | 28.8 | 13.7 | 10.7 | 7.2 |
400 | 43.7 | 28.7 | 25.8 | 11.2 | 8.2 | 6 |
500 | 49.3 | 26.1 | 23.2 | 9.3 | 6.3 | 6 |
Part Number | Description | Standard Length |
114-202NH204X | Category 6A F/UTP 4 Pair 23 AWG Double Jacket Galvanized Iron Wire
Armoured Cable -LDPE/HDPE | 305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)