INTELLIGENT ADDRESSABLE FIRE ALARM CONTROL PANEL NFA-T04FP

The NFA-T04FP Intelligent Fire Alarm Control Panel is microprocessor-based, analogue addressable, and offers customers flexibility in terms of both functionality and design. The NFA-T04FP Intelligent Fire Alarm Control Panel is designed and manufactured to meet the standards of BS EN 54-2&4. This would provide customers with early notice of any fire and the trouble status of device on the property. It would also help to identify the location of any fires and enable preventive measures to be taken as per cause-and-effect requirement configured through command builder set up. like Elevator Control, Air Handling shut down, Gas shut off and Damper control etc. Moreover, dedicated circuits provided for Notification Appliances which allows the panel to give quick alert to the tenants to evacuate the premise.

The NFA-T04FP Intelligent Fire Alarm Control Panel is microprocessor-based, analogue addressable, and offers customers flexibility in terms of both functionality and design. The NFA-T04FP Intelligent Fire Alarm Control Panel is designed and manufactured to meet the standards of BS EN 54-2&4. This would provide customers with early notice of any fire and the trouble status of device on the property. It would also help to identify the location of any fires and enable preventive measures to be taken as per cause-and-effect requirement configured through command builder set up. like Elevator Control, Air Handling shut down, Gas shut off and Damper control etc. Moreover, dedicated circuits provided for Notification Appliances which allows the panel to give quick alert to the tenants to evacuate the premise.

SCOPE OF THE SYSTEM

  • LPCB approved
  • EN 54-2 :1997 + A1:2006,EN 54-4:1997 + A1:2002+ A2 :2006 certified
  • Networkable
  • LCD Touchscreen and Keypad access for user interface
  • Advanced microprocessor technology with large memory capacity
  • PC and Keypad programming
  • Support real time visual algorithm
  • False alarm prevention
  • USB/Ethernet/CanBus/Serial/RS485 built in interface protocol (Available only in NFA-T04FP Panel)
  • Built in printer and 160 led zones indicators
  • Loop powered devices supports

  • SYSTEM FEATURES

    254 devices per loop
    Maximum 4 loop in Network application
    Built in 4 in 1 communication card
    6 Loop can support in stand alone basis
    Networkable upto 512 Nodes
    Dedicated 2 loop for NAC
    Programmable capacity
    Sounder groups 1-1000
    Module groups 1001-2000
    Zones up to 3000
    Built -in 160 LED Zones indicator


    PROGRAMMING ADVANTAGES

    Command Builder to create requirements for fire event scenario
    Auto enrolling of devices
    Monitor device mismatch and dual address conflict
    Loop protection against power surge
    Loop mapping with color coding status
    One man test with on/off sounder programming protection


    TECHNICAL INFORMATION

    Characteristic

    Value

    ListedLPCB
    CertifiedEN 54-2 :1997 + A1:2006,EN 54-4:1997 + A1:2002+ A2 :2006 Certified
    No. of Loop4 Loop 
    AddressingValue range from 1 to 254
    ProtectionBuilt in 4KV surge protection
    Power Rating 16 to 24 VDC 
    Cabling1KM max length 2 x 1.5 mm² solid core Fire resistance
    Panel Topanel CommunicationCan Bus[loop] 
    Interface CardsUSB,RS485 Serial,RS232 Serial,Ethernet
    Input Voltage 230 VAC + 10%-15%, 50/60Hz
    Input Current Consumption2A
    PSU Output To CIE21.5 to 28.5 VDC
    Batteries2 x 12V/28 AH 
    Memory (Non-Volatile) 1000 Fire events,10000 General event
    Zones3000 Programmable
    Total Group3000 Programmable
    Sounder Group 1000 Programmable
    Common Group2000 Programmable
    Display7" TFT Touch screen
    Keypad 5 Brigade buttons and programming keypad
    Programmable Input1 Circuit: Power limited 24 VDC (for future use) 
    Programmable Relays4 Circuits : Normally Open/Close
    Programmable Auxiliary Power19 To 28 VDC (Note :Current limited) 
    Fixed Outputs(FPE/Sounder) 2 Circuits: 18 to 28 VDC (Note: Current limited)
    Indicator24 LED Status/ 160 Zone Indicators 
    Material/colourFlat Sheet Metal With Outer Glass Door/Silver Stripe
    Dimension L x W x H 530 mm x 490 mm x 135 mm
    Weight16.7 Kg
    Humidity0 to 95% Relative Humidity,Non condensing
    Temperature-5˚C to + 40˚C 






    ORDERING INFORMATION

    Part Number

    Description

    NFA-T04FP

    4 Loop LPCB Approved. 7" LCD display touch screen, Fitted with 2x Dual loop card, basic configuration up to 1016 Addressable Devices, Expandable to 6 loop by adding loop.Built in Glass Door and Printer. Built in 4 in 1 Communication card

    NFA-T04-2FP2 Loop LPCB Approved. 7" LCD display touch screen, Fitted with 1x Dual loop card, basic configuration up to 508 Addressable Devices, Expandable to 6 loop by adding loop card.Built in Glass Door and Printer. Optional 4 in 1 Communication card.
    NFA-T04-1FP 1 Loop LPCB Approved. 7" LCD display touch screen, Fitted with 1x single loop card, basic configuration up to 254 Addressable Devices, Expandable to 6 loop by adding loop card.No Glass Door, Optional Printer and 4 in 1 Communication card.