The cable is constructed with FRP Central Strength Member, two layer tubes with Jelly Compound for double water blocking, Aramid yarn strength member for better tensile strength and rodent protection, FR PVC outer Jacket with metric print. Non-metallic structure and good electro-magnetic resistance makes it a good choice for use in High voltage and thunder prone areas. The cable is suitable for internal, external and long distance communication system. The cable has options of LSZH, PE & Plenum outer jacket as per customer request. The cable contains robust characteristics of external cable and flexibility of internal cable. By installing this cable, costly splice at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).
The cable is constructed with FRP Central Strength Member, two layer tubes with Jelly Compound for double water blocking, Aramid yarn strength member for better tensile strength and rodent protection, FR PVC outer Jacket with metric print. Non-metallic structure and good electro-magnetic resistance makes it a good choice for use in High voltage and thunder prone areas. The cable is suitable for internal, external and long distance communication system. The cable has options of LSZH, PE & Plenum outer jacket as per customer request.
The cable contains robust characteristics of external cable and flexibility of internal cable. By installing this cable, costly splice at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).
COMPLIANCEITU-T G651.1 OM1 OM2 OM3 OM4 IEC60793-2-10 type A1a.1/A1b OM1/OM2 IEC60793-2-10 type A1a.2 OM3 IEC60793-2-10 type A1a.3 OM4 ISO/IEC 11801 , ISO/IEC 24702 ANSI/TIA/EIA 568C.3 ROHS compliant Directive 2002/95/EC IEC 60332, IEEE 1202 ANSI/TIA-568-C.1, UL 1666 |
Characteristics | Value | |
Max. Tensile Load | 3000 N | 1000 N |
Max. Crush Load | 2000 N/100 mm | 1000 N/100 mm |
Operating Temp. | -20 °C to +60 °C | |
Storage Temp. | -40 °C to +85 °C | |
UL Rating | OFNR | |
Sheath Material | FRPVC |
Part Number | Fibre Count | Outer Diameter (mm) | Cable Weight (kg/km) | Bend Radius | |
Short (mm) | Long (mm) | ||||
3107-71004FXXCL | 4 | 10.0 | 98.0 | 20D | 10D |
3107-71006FXXCL | 6 | 10.0 | 98.0 | 20D | 10D |
3107-71008FXXCL | 8 | 10.0 | 98.0 | 20D | 10D |
3107-71012FXXCL | 12 | 10.0 | 98.0 | 20D | 10D |
3107-71024FXXCL | 24 | 10.0 | 98.0 | 20D | 10D |
3107-71036FXXCL | 36 | 10.0 | 98.0 | 20D | 10D |
3107-71048FXXCL | 48 | 11.5 | 120.0 | 20D | 10D |
3107-71072FXXCL | 72 | 11.5 | 120.0 | 20D | 10D |
3107-71096FXXCL | 96 | 13.6 | 154.0 | 20D | 10D |
3107-71144FXXCL | 144 | 17.5 | 275.0 | 20D | 10D |