Norden Category 5E UTP stranded cables exceed Category 5E / Class D specification. It is tested to 100 MHz frequency range and designed to support Gigabit 1000Base-T applications upto 100m. Norden Category 5E UTP cables are having standard packing in 305m easy pull out boxes. By design, Norden cables are manufactured to the highest quality standards, design requirements and materials to ensure that every box provides significant margin over ANSI/TIA-568.2-D specifications for NEXT, Power Sum NEXT and Insertion Loss across the entire channel.
Norden Category 5E UTP stranded cables exceed Category 5E /
Class D specification. It is tested to 100 MHz frequency range and
designed to support Gigabit 1000Base-T applications upto 100m.
Norden Category 5E UTP cables are having standard packing in
305m easy pull out boxes.
By design, Norden cables are manufactured to the highest quality
standards, design requirements and materials to ensure that
every box provides significant margin over ANSI/TIA-568.2-D
specifications for NEXT, Power Sum NEXT and Insertion Loss
across the entire channel.
Product Sequence | Premium |
Product Type | Twisted Pair Cable |
Conductor Material | Bare Copper |
Conductor Size | 7/0.18 mm, 24 AWG |
Conductor Construction | Stranded |
Insulation Material | High Density PE |
Insulation Diameter | 0.88±0.05 mm |
Conductor Unit Identification | Stranded/Stripe |
Colour Code | Per TIA/EIA 568-B |
Total Number of Wires | 8 |
Seperator | Yes |
Outer Jacket | LSZH / PVC |
Outer Jacket Thickness & Ex. Diameter | 0.50±0.05 mm, 5.4±0.20 mm |
Outer Jacket Colour | Per Requirement |
Marking | Per Requirement |
Frequency Range | 1-100 MHz |
Impedance | 100Ω ±15 |
Coupling Attenuation | 40 dB min @ 30-100 MHz |
Max. DC Resistance | 89 Ω/km @ 20 °C. |
Max.Resistance Unbalance | 5 % |
Capacitance | 5.6 nF/100m Max |
Capacitance Unbalance | 3.3 pF/m max |
Velocity of Propagation | 69% |
Propagation Delay Skew | 25 ns/10m max |
Dielectric Strength | 1 KV/Minute |
Min. Insulation Resistance | 5 GΩ•km |
Max. Tensile Strength - Short Term | 110N |
Min. Bend Radius | 40 mm |
Operating Temperature Range | -30 °C +60 °C |
Freq. MHz |
Attenuation dB/100m @ 20ºC |
NEXT dB |
PSNEXT dB |
RL dB |
ACR-N dB |
PS ACR-N dB |
1 | 3.0 | 60.0 | 57.0 | 17.0 | 57.0 | 54.0 |
4 | 4.5 | 53.5 | 50.5 | 17.0 | 49.1 | 46.1 |
10 | 7.1 | 47.0 | 44.0 | 17.0 | 39.9 | 36.9 |
20 | 10.2 | 42.0 | 39.0 | 17.0 | 31.8 | 28.8 |
31.25 | 12.9 | 38.7 | 35.7 | 15.1 | 25.9 | 22.9 |
62.5 | 18.6 | 33.6 | 30.6 | 12.1 | 15.0 | 12.0 |
100 | 24.0 | 30.1 | 27.1 | 10.0 | 6.1 | 3.1 |
Part Number | Description | Standard Length |
118-10001104X |
Category 5E U/UTP 24AWG 4 Pair Stranded Cable PVC |
305 mtr |
118-10002104X |
Category 5E U/UTP 24AWG 4 Pair Stranded Cable LSOH |
305 mtr |
X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow)