CATEGORY 6 F/UTP 4 PAIR 24 AWG CABLE

CATEGORY 6 F/UTP 4 PAIR 24 AWG CABLE

Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Cross talk performance.

Norden Category 6 F/UTP cables exceed Category 6 / Class E specification. It is tested to 250 MHz frequency range and designed to support Gigabit 1000Base-T and 1000Base-Tx applications up to 100m. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to F/UTP (Foiled Twisted Pair) cabling systems. F/UTP (Twisted Pair – overall Foil shield) cabling systems are installed for improved Alien Cross talk performance.



PRODUCT CLASSIFICATION


Product Sequence Euro Class
Product Type Twisted Pair Cable


MATERIAL CONSTRUCTION & DESIGN


Conductor Material Bare Copper
Conductor Size 24 AWG
Conductor Construction Solid
Insulation Material High Density PE
Insulation Diameter 1.05 mm
Conductor Unit Identification Solid/Stripe
Drain Wire Tinned Copper 0.41 mm
Overall Shield Mylar +Aluminium/Mylar
Outer Jacket LSZH
Outer jacket Thickness & Ex. Diameter 0.60±0.05 mm, 6.9±0.4 mm
Colour Code Per TIA/EIA 568-B
Total Number of Wires 8
Rip Cord Yes


ELECTRICAL & MECHANICAL CHARACTERISTICS


Pulling Force: 110 N/mm max
Delay Skew: 1-250 MHz ns/100m ≤or equal to 45
Tensile Strength ≥10 Mpa
Elongation ≥125 %
Characterstics 100±15Ω @ 1-250 MHz
DC Resistance 9.38(Ω/100m) max.
DC Conductor Resistance Unbalance: 5.0 % max
Capacitance Max 5.6 nF/100m.
Cap. Unbalance (Wire to Ground) Max 330 pF/100m
Dielectric Strength 1.0 KV/minute
Velocity of Propagation 69 %
Insulation Resistance: 5000 MΩ Km/min.
Transfer Impedance N/A
Cold Bend (-20D Celcius x 4h) 8 x OD mm., No visible Cracks
Operating Temperature: -10 to +65?C


ELECTRICAL PERFORMANCE CHARACTERISTICS

Cat. 6 Un-screened Pair Horizontal Cables*

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
DELAY
ns
RL
dB
ELFEXT
dB
PSELFEXT
dB
1.0 2.03 74.3 72.3 570 20 67.8 64.8
4.0 3.78 65.3 63.8 552 23 55.8 52.8
8.0 5.32 60.8 58.8 546.73 24.5 49.7 46.7
10 5.95 59.3 57.3 545.38 25 47.8 44.8
16 7.55 56.2 54.2 543 25 43.7 40.7
20 8.47 54.8 52.8 542.05 25 41.8 38.8
25 9.51 53.3 41.3 541.2 24.3 39.8 36.8
31.25 10.67 51.9 49.9 540.44 23.6 37.9 34.9
62.5 15.38 44.7 45.4 538.55 21.5 31.9 28.9
100 19.8 44.3 42.3 573.6 20.1 27.8 24.8
200 28.98 39.8 37.8 536.54 18 21.8 18.8
250 32.85 38.3 36.3 536.27 17.3 19.8 16.8

*Supplied cables meet the minimum Cat. 6 transmission requirements as per IEC 61156-5 Ed. 2

Part Number Description Standard Length
120-1000E204X Category 6 F/UTP 4 Pair 24 AWG Cable LSOH (Eca) 305 mtr

X: BK(Black), BL(Blue), GN(Green), GY(Gray), RD(Red), WH(White), YL(Yellow), PU(Purple)