NORDEN External Telephone Cables are designed to connect telephone and communication equipment reliably. These cables can also be used for other communication, control systems, or low-level signalling. With PE Insulation, PE Inner, and an LSZH Outer, the cables meet high performance standards. They are ideally suited for both underground and direct-buried installations
NORDEN External Telephone Cables are designed to connect telephone and communication equipment reliably. These cables can also be used for other communication, control systems, or low-level signalling. With PE Insulation, PE Inner, and an LSZH Outer, the cables meet high performance standards. They are ideally suited for both underground and direct-buried installations
Conductor | Single solid bare copper |
Insulation | PE |
Screening | Aluminium tape |
Braiding | Copper wire braid (65% coverage) |
Inner Sheath | PE |
Armouring | Steel wire |
Outer Jacket | LSZH |
Characteristic | Value | ||
2 Core | 4 Pair | 50 Pair | |
Conductor Size | 16AWG(1.29mm) | 18AWG (1.0mm | 18AWG (1.0mm) |
Nom. Insulated Diameter(mm) | 2 | 1.8 | 1.8 |
Inner Sheath Diameter(mm) | 5 | 11.5 | 137 |
Inner Sheath Thickness(mm) | 0.8 | 1.2 | 1.5 |
Steel Wire Diameter(mm) | 0.9 | 1.25 | 1.6 |
Outer Sheath Diameter(mm) | 9.4 | 17.6 | 45 |
Outer Sheath Thickness(mm) | 1.3 | 1.6 | 2 |
Min. Bending Radius | 12*OD | ||
Operating Temperature | -5 °C to +70 °C |
Characteristic | Unit | Value |
Peak operating voltage | V | 300 |
Test voltage wire/wire | V | 800 |
Test voltage wire/shield | V | 800 |
Attenuation at 800 Hz | dB/km | 1.1 |
Insulation- specific volume resistance | MΩ/km | 100 |
Pairs | Primary | Secondary |
1 | White | Blue |
2 | White | Orange |
3 | White | Green |
4 | White | Brown |
5 | White | Grey |
6 | Red | Blue |
7 | Red | Orange |
8 | Red | Green |
9 | Red | Brown |
10 | Red | Grey |
11 | Black | Blue |
12 | Black | Orange |
13 | Black | Green |
14 | Black | Brown |
15 | Black | Grey |
16 | Yellow | Blue |
17 | Yellow | Orange |
18 | Yellow | Green |
19 | Yellow | Brown |
20 | Yellow | Gray |
21 | Violet | Blue |
22 | Violet | Orange |
23 | Violet | Green |
24 | Violet | Brown |
25 | Violet | Grey |
26 | White | Blue |
27 | White | Orange |
28 | White | Green |
29 | White | Brown |
30 | White | Grey |
31 | Red | Blue |
32 | Red | Orange |
33 | Red | Green |
34 | Red | Brown |
35 | Red | Grey |
36 | Black | Blue |
37 | Black | Orange |
38 | Black | Green |
39 | Black | Brown |
40 | Black | Gray |
41 | Yellow | Blue |
42 | Yellow | Orange |
43 | Yellow | Green |
44 | Yellow | Brown |
45 | Yellow | Gray |
46 | Violet | Blue |
47 | Violet | Orange |
48 | Violet | Green |
49 | Violet | Brown |
50 | Violet | Gray |
Part Number | Description | Conductor Diameter (mm) |
212-18162002 | 2 Core External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1.29 |
212-18122004 | 4 Pair External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1 |
212-18122050 | 50 Pair External Telephone Cable PE Insulation/PE Inner/LSZH Outer | 1 |