E-Glass Strength Central Loose Tube Armoured In/Out Fibre Optic Cable

E-Glass Strength Central Loose Tube Armoured In/Out Fibre Optic Cable

This cable is constructed with, Central Loose Tube with Jelly Compound which gives water and moisture protection. E-glass gives better tensile strength and protection. High Mechanical and full rodent protection provided by Corrugated steel tape (CTS) armour. The cable has excellent UV-stabilized and water blocking performance for external duct application (PE outer jacket) or Internal / External application (LSZH outer jacket). By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).

This cable is constructed with, Central Loose Tube with Jelly Compound which gives water and moisture protection. E-glass gives better tensile strength and protection. High Mechanical and full rodent protection provided by Corrugated steel tape (CTS) armour. The cable has excellent UV-stabilized and water blocking performance for external duct application (PE outer jacket) or Internal / External application (LSZH outer jacket). By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).

COMPLIANCE

ITU-T G652.B OS1
ITU-T G652.D/G655/G657.A1/G657.A2 OS2
ITU-T G651.1 OM1 OM2 OM3 OM4
IEC60793-2-10 type A1a.1/A1b OM1/OM2
IEC60793-2-10 type A1a.2 OM3
IEC60793-2-10 type A1a.3 OM4
ISO/IEC 11801 , ISO/IEC 24702
ANSI/TIA/EIA 568C.3
ROHS compliant Directive 2002/95/EC
LSZH: IEC 60332-1, IEC 60754, IEC 61034

MECHANICAL & ENVIRONMENTAL CHARACTERISTICS

Characteristic Short Term Long Term

Pulling tension

2000 N

800 N

Max. Crush Load

30 KN/m

Operating Temp.

-20 °C to +70 °C

Storage Temp.

-40 °C to +85 °C

Sheath Material

Standard: LSZH Optional: PVC, PE or other

Part Number Fibre Count Outer Diameter
(mm)
Cable Weight
(kg/km)
Bend Radius
Short
(mm)
Long
(mm)

3147-21004FXXCL

4

9.3

103

20D

10D

3147-21006FXXCL

6

9.3

103

20D

10D

3147-21008FXXCL

8

9.3

103

20D

10D

3147-21012FXXCL

12

9.3

103

20D

10D

3147-21016FXXCL

16

9.3

103

20D

10D

3147-21024FXXCL

24

9.3

103

20D

10D