PH120 STRANDED CONDUCTOR SHIELDED FIRE RESISTANT CABLE

PH120 STRANDED CONDUCTOR SHIELDED FIRE RESISTANT CABLE

NORDEN FireNor PH120 fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases

NORDEN FireNor PH120 fire resistant cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products have low smoke density, are halogen free and they don't emit poisonous gases

CABLE CONSTRUCTION


ELECTRICAL & MECHANICAL CHARACTERISTICS

Properties Value

1.5mm2                         2.5mm2
Max. Conductor Resistant @ 20ºC
13.30Ω/km                    7.98Ω/km
Min. Insulation Resistant @ 0ºC
200 MΩxkm
Operating Voltage
300/500 V
Test voltage 2000V
Temperature Rating (Fixed)
-30ºC to + 90ºC
Temperature Rating (Flexing)
-10ºC to + 90ºC
Min. Bend Radius (Fixed)
8 x D
Min. Bend Radius (Flexing)
15 x D

PHYSICAL CHARACTERISTICS

Nom Conductor Cross Section mm2Conductor Diameter, mm(±5 %)Copper Weight (Kg/km)Weight Kg/km

2X1.5

8.0

28.66

76.31

2X2.5

9.46

44.71

108.67

PART NUMBERDESCRIPTION

53-1502X

PH120 Stranded Conductor Shielded Fire Resistant Cable, 2C x 1.5mm²

53-2502X

PH120 Stranded Conductor Shielded Fire Resistant Cable, 2C x 2.5mm²

X > OR:Orange, RD: Red