NORDEN Fire Resistant Cable PH 120 SFR Insulation cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products_backup have low smoke density, are halogen free and they don't emit poisonous gases.
NORDEN Fire Resistant Cable PH 120 SFR Insulation cables are manufactured within the specific requirement of fire resistant cable standards. The fire resistant cable assures reliable circuit integrity to keep emergency evacuation systems operational even whilst the cable is burning. FireNor fire resistant cables can be used for fire alarm systems, power supply or control of equipment that needs to function during a fire such as warning, emergency lighting, evacuation and monitor systems. The place of usage is intelligent or semi-intelligent buildings where dense human population or valuable goods are found. These can be hospitals, cinemas, theatres, schools, shopping centers, airports, factories, hotels etc. FireNor products_backup have low smoke density, are halogen free and they don't emit poisonous gases.
ConductorSolid Bare Copper |
ScreenAluminium Laminated Polyester Tape |
SheathHFFR EN 50290-2,BS 7655 LTS1/LTS3 |
InsulationFire resistant silicon rubber |
SeparatorPolyester Type |
Sheath ColorRed (RAL 3000) or White |
Insulation Colour2 Core: Blue/Brown |
Earth WireTinned Copper to IEC 60228 |
Standard Packing Mode100 mtr / Plywood Reel |
Flame Tests | Insulation Integrity | Smoke Density | Corrosive Gases Measurement | Other Stanaderds |
IEC 60332-1 |
IEC 60331 |
IEC 61034 |
IEC 60754-2 |
BS 7629-1: 2008 BS 8519 (Clause 11) BS 5266-1 (Clause 8.2.2a) BS 8539-6 (Clause 16.2) BS 5839-8 (Clause 27.6) BS 5839-1:2013 (Clause 26.2d Standard) |
Properties | Value | ||
1.5 mm² | 2.5 mm² | 4.0 mm² |
|
Max. Conductor Resistant @ 20ºC |
12.0Ω/km |
7.4 Ω/km | 4.5 Ω/km |
Min. Insulation Resistant @ 20ºC |
200 MΩ/km |
||
Operating Voltage |
300/500 V |
||
Test Voltage |
2000 V |
||
Temperature Range (Fixed) |
-30ºC to + 90ºC |
||
Temperature Range (Flexing) |
-5ºC to + 60ºC |
||
Min. Bend Radius (Fixed) |
8 x D |
||
Min. Bend Radius (Flexing) |
15 x D |
Nom. Cond. Cross-Sect. mm² |
Conductor Size no./mm |
Earth Wire Size no./mm |
Cable Diameter mm (±5 %) |
Weight Kg/km |
2 x 1.5 |
1/1.37 |
1/1.37 |
8.00 |
98.0 |
2 x 2.5 |
1/1.75 |
1/1.75 |
9.70 |
148.0 |
Part Number | Description |
55-1502X |
Fire Resistant Cable PH120 SFR Insulation, 2C x 1.5mm² |
55-2502X |
Fire Resistant Cable PH120 SFR Insulation, 2C x 2.5 mm² |
55-4003X | Fire Resistant Cable PH120 SFR Insulation, 3C x 4 mm² |
X > RD:Red WH:White OR:Orange