External Telephone Cables from NORDEN are primarily designed for the interconnection of telephone equipment. In addition, these cables may be used for interconnection of other communication and control equipment or low level signaling applications. The cables are suitable for fire resistant applications and duct laying. This fire resistant cables are having special insulation of Flame Retardant PE Outer jacket & PBT insulation. It is specially used in oil field applications.editted
External Telephone Cables from NORDEN are primarily designed for the interconnection of telephone equipment. In addition, these cables may be used for interconnection of other communication and control equipment or low level signaling applications. The cables are suitable for fire resistant applications and duct laying. This fire resistant cables are having special insulation of Flame Retardant PE Outer jacket & PBT insulation. It is specially used in oil field applications.editted
Conductor |
Class 1 Solid annealed Bare Copper Conductors to BS 6360:1991/IEC 60228:2005 (Note - IEC 60228:2005 replaces BS 6360:1991) |
Insulation |
PBT |
Twisted Pair |
Two single wires are twisted to form a Pair |
Separator |
Polyester Tape and Water Blocking Tape Both helically wrapped |
Core Filler |
Petroleum Jelly Compound |
Screening |
AL Tape Laminated with FR PE-Copolymer Longitudinal Wrapped |
Outer Jacket |
FR PE (Flame Retardant Polyethylene) |
Jacket Colour |
Black |
Characteristic | Value | ||
0.4 mm | 0.5 mm | 0.63 mm | |
Conductor Size | 26 AWG | 24 AWG | 22 AWG |
Nom. Insulation Thickness | 0.175 mm | 0.20 mm | 0.26 mm |
Nom. Insulated Conductor Diameter | 0.75 mm | 0.90 mm | 1.15 mm |
Min. Bending Radius | 10 x D | ||
Operating Temperature |
-20 °C to +70 °C |
Characteristic | Unit | Value | ||
0.4 mm | 0.5 mm | 0.63 mm | ||
Max. Conductor DC Resistant @ 20 °C | Ω/km | 143 | 91 | 58 |
Min. Insulation Resistant @ 500 VDC | MΩ.km | 1500 | 1500 | 1500 |
Max. Average Mutual Capacitance @ 800 Hz | nF/km | 56 | 56 | 56 |
Max. Capacitance Unbalance @ 800 Hz (Pair to Pair) | pF/500m | 275 | 275 | 275 |
Pair Colour Code | Unit Binder Colour Code | |||
Pair No. | Wire - A Colour | Wire - B Colour | Unit No. | Binder Tape Colour |
1 |
White |
Blue |
1 |
Blue |
2 |
White |
Orange |
2 |
Orange |
3 |
White |
Green |
3 |
Green |
4 |
White |
Brown |
4 |
Brown |
5 |
White |
Grey |
5 |
Grey |
6 |
Red |
Blue |
6 |
White |
7 |
Red |
Orange |
7 |
Red |
8 |
Red |
Green |
8 |
Black |
9 |
Red |
Brown |
9 |
Yellow |
10 |
Red |
Grey |
10 |
Violet |
Part Number | Description | Conductor Diameter (mm) |
Pair Config. |
Min. Sheath Thickness (mm) |
Max. Overall Diameter (mm) |
212-03015005 |
0.4mm 005 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
1 x 5P |
1.1 |
9.0 |
212-03015010 |
0.4mm 010 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
1 x 10P |
1.1 |
10.0 |
212-03015020 |
0.4mm 020 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
2 x 10P |
1.1 |
11.5 |
212-03015030 |
0.4mm 030 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
3 x 10P |
1.1 |
13.3 |
212-03015050 |
0.4mm 050 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
5 x 10P |
1.2 |
15.5 |
212-03015100 |
0.4mm 100 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
10 x 10P |
1.3 |
20.0 |
212-03015150 |
0.4mm 150 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
3 x 50P |
1.4 |
23.8 |
212-03015200 |
0.4mm 200 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.4 |
4 x 50P |
1.4 |
26.7 |
212-03025005 |
0.5mm 005 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
1 x 5P |
1.1 |
9.5 |
212-03025010 |
0.5mm 010 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
1 x 10P |
1.1 |
11.0 |
212-03025020 |
0.5mm 020 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
2 x 10P |
1.2 |
13.5 |
212-03025030 |
0.5mm 030 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
3 x 10P |
1.2 |
15.3 |
212-03025050 |
0.5mm 050 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
5 x 10P |
1.3 |
18.0 |
212-03025100 |
0.5mm 100 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
10 x 10P |
1.4 |
23.5 |
212-03025150 |
0.5mm 150 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
3 x 50P |
1.5 |
27.8 |
212-03025200 |
0.5mm 200 Pair Jelly Filled Cable CW 1128/1179 FR PE |
0.5 |
4 x 50P |
1.5 |
31.3 |