Norden's Ultra power series 100-200kVA UPS is an online Transformer-based UPS which has three phase in both input and output and an output power factor of 0.9.This UPS Features an isolation transformer in the output side to provide galvanic isolation for the load connected and a 6 pulse rectifier and an optional 12 pulse rectifier model which can reduce the harmonic currents and increase the power factor considerably by reducing the amount of reactive power consumed.
Norden's Ultra power series 100-200kVA UPS is an online Transformer-based UPS which has three phase in both input and output and an output power factor of 0.9.This UPS Features an isolation transformer in the output side to provide galvanic isolation for the load connected and a 6 pulse rectifier and an optional 12 pulse rectifier model which can reduce the harmonic currents and increase the power factor considerably by reducing the amount of reactive power consumed.
Model | CN433100TU | CN433120TU | CN433160TU | CN433200TU | |
Capacity | kVA | 100kVA | 120kVA | 160kVA | 200kVA |
Watts | 90kW | 108kW | 144kW | 180kW | |
Input | Normal Voltage | 380/400/415Vac (3Ph+N+PE) (-25% +20%) | |||
Operating frequency range | 50/60Hz (±5Hz) | ||||
Power factor | ≥0.97 (with | ||||
Bypass voltage range | Upper limit:+20%(+10%,+15%,+20% adjustable) Lower limit:-40%(-10%,-20%,-30%,-40% adjustable) | ||||
Bypass Frequency range | ±10%(±2.5%,±5%,±10%,±20% adjustable) | ||||
Output | Rated voltage | 380/400/415Vac (3Ph+N+PE) | |||
Power factor | 0.9 | ||||
Voltage regulation | ±1% | ||||
Frequency | 50/60(±0.05)Hz
| ||||
Crest factor | 3:1 | ||||
Harmonic distortion (THDv) | ≤2% with linear load | ||||
Efficiency | >92% >92.5%
| ||||
Output Waveform | Pure SineWave | ||||
Battery | Battery voltage | 384Vdc (30/32/34pcs)
| |||
System Features | Transfer time | Mains to battery:0ms;
| |||
Overload | 110%60min, 125%10min, 150%1min | ||||
LED Display | Input, Inverter, Bypass, Battery, Output, Status | ||||
LCD Display | I/O voltage, frequency, power, power factor, battery voltage, current, battery status, load percentage,
UPS status, history record, settings | ||||
Communication | USB, RS232, RS485, Parallel port, dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) | ||||
Environment | Operating temperature | 0~40°C | |||
Storage temperature | -25~55°C | ||||
Humidity range | 0~95% (Non-condensing)
| ||||
Altitude | <1500m | ||||
Noise level | <68dB | ||||
Physical | Dimension WxDxH(mm) | 720x690x1400 (6P) 890x790x1600 (6P) 890x790x1600 (6P) 1200x800x1600 (6P) 1515x830x1600 (12P) 1515x830x1600 (12P) 1400x1000x1900 (12P) 1400x1000x1900 (12P) | |||
Net Weight (kg) | 566/1300 | 693/1450 | 780/1645 | 1030/1715 | |
Standards | Safety | IEC/EN62040-1,IEC/EN62477-1 | |||
EMC | IEC/EN 62040-2;IEC 61000-2-2;IEC 61000-4-2;IEC 61000-4-3;IEC 61000-4-4 IEC 61000-4-5;IEC 61000-4-6;IEC 61000-4-8;IEC 61000-4-11
| ||||
Performance | IEC62040-3 |
Part Number | Description | ||
CN433100TU | 100kVA Double Conversion Transformer-Based 3/3 UPS (External Battery | ||
CN433120TU | 120kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)
| ||
CN433160TU | 160kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)
| ||
CN433200TU | 200kVA Double Conversion Transformer-Based 3/3 UPS (External Battery)
|
Part Number | Description | ||
CNS01 | SNMP Card |