Cat 6 S/FTP Double Jacket Steel Tape Armoured External Cable PVC/PE

Norden Category 6 S/FTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications.Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to S/FTP (Shielded Twisted Pair) cabling systems. Cat 6 S/FTP armoured Cable Consists of PE Insulated 23AWG Solid Bare Annealed Copper Conductors, twisted 4 pair stranded, ECCS tape Armour, PVC Inner sheath and PE (UV Stabilized) Outer sheath.

Norden Category 6 S/FTP armoured cables exceed Category 6 /Class E specification. It is tested to 250MHz frequency range and designed to support 1000Base-T and 1000Base-Tx applications. Extremely high pair-balance providing excellent EMC (Electro Magnetic Compatibility), minimizing radiation, maximizing noise immunity and providing high alien cross talk performance to S/FTP (Shielded Twisted Pair) cabling systems. Cat 6 S/FTP armoured Cable Consists of PE Insulated 23AWG Solid Bare Annealed Copper Conductors, twisted 4 pair stranded, ECCS tape Armour, PVC Inner sheath and PE (UV Stabilized) Outer sheath.


COMPLIANCE

IEEE 802.3an :2006 (10GBASE-T)
ANSI/TIA 568.2-D

ISO/IEC-11801, 2nd Edition Class E

IEC 61156-5:2002 Category 6

 

MATERIAL CONSTRUCTION & DESIGN

Conductor Material

Solid Bare Copper

Conductor Size

23 AWG

Conductor Construction

Solid

Insulation Material

Polyethylene

Insulation O.D

<=1.35mm

Conductor Unit Identification

Solid/Stripe

Colour Code

Per TIA/EIA 568-B

Conductor Unit Lay-Up

Pairs

Total Number Of Wires

8

Individual Shield Material

100% Mylar Tape (AL/PET)

Overall Braiding

40% Tinned Copper

Inner Jacket Material

PVC

Armour

? 0.125mm

Outer Jacket Material

LDPE

Outer Cable Diameter

12.6±1.5 mm

Outer Jacket Colour

Black

ELECTRICAL & MECHANICAL CHARACTERISTICS

Conductor Resistance @20°C

Max. 93.8 ?/KM

Conductor Resistance Unbalance

Max. 5 %

Mutual Capacitance @1KHZ

Max. 56 nF/KM

Insulation Resistance

min. 5000 M?.km

High Voltage

2.5 Kv DC/1 min

Capacitance Earth Unbalance

Max. 3300 pF/km

Propagation Delay @ 1, 10, 100 &250 MHz

Max. 570, 545,538 & 536ns/100 m

Propagation DeLay Skew 1 – 250 MHz

Max. 40 ns/100 m

Characteristic Impedance (1-250 MHz)

100 ± 15?

Bending Radius

15 x Diameter(min.)

Pulling Force

11.5 kgs(max.)

Temperature Range

-20°C up to +60°C

TRANSMISSION PERFORMANCE

Electrical Characteristics meet or exceed 70 Meter TIA Cat 6 Channel Spec.

Freq.
MHz
Attenuation
dB/100m @ 20°C
NEXT
dB
PSNEXT
dB
RL
dB
ELFEXT
dB
PSELFEXT
dB
1 2.1 65.0 62.0 19.0 63.3 60.3
4 4.0 63.0 60.5 19.0 51.2 48.2
8 5.7 58.2 55.6 19.0 45.2 42.2
10 6.3 56.6 54.0 19.0 43.3 40.3
16 8.0 53.2 50.6 18.0 39.2 36.2
20 9.0 51.6 49.0 17.5 37.2 34.2
25 10.1 50.0 47.3 17.0 35.3 32.3
31.25 11.4 48.4 45.7 16.5 33.4 30.4
62.5 16.5 43.4 40.6 14.0 27.3 24.3
100 21.3 39.9 37.1 12.0 23.3 20.3
200 31.5 34.8 31.9 9.8 17.2 14.2
250 35.9 33.1 30.2 8.0 15.3 12.3



Part Number Description Standard Length

113-20813504X

Cat 6 S/FTP Double jacket Steel Tape Armored External Cable PVC/PE

305 mtr

X: BK(Black)