This cable is constructed with Central Loose Tube and E-glass gives better tensile strength and protection. High Mechanical and full rodent protection provided by Corrugated steel tape (CTS) armour.The cable has excellent UV-Stabilized and water blocking performance for external duct application (PE outer jacket) with Gel free fibre cable construction. By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).
This cable is constructed with Central Loose Tube and E-glass gives better tensile strength and protection. High Mechanical and full rodent protection provided by Corrugated steel tape (CTS) armour.The cable has excellent UV-Stabilized and water blocking performance for external duct application (PE outer jacket) with Gel free fibre cable construction. By installing this cable costly splicing at building entry can be avoided and cable can be routed from outside plant to telecommunication closets or main distribution frames (MDF) through the riser of building and eliminate the “50 foot rule” for external cables. The cable is mostly used in LAN application for intra building backbone and interconnections (Campus LAN).
COMPLIANCEITU-T G652.B OS1 |
Characteristic | Short Term | Long Term |
Pulling tension |
1600 N |
800 N |
Max. Crush Load |
30 KN/m |
|
Operating Temp. |
-20 °C to +60 °C |
|
Storage Temp. |
-40 °C to +85 °C |
|
Sheath Material |
HDPE |
Fibre Type |
Max. Attenuation |
Min. Overfill Launch |
Min. Gigabit Ethernet Link |
||||||
Gigabit |
10Gigabit |
||||||||
850nm |
1300nm |
1310nm |
1550nm |
850nm |
1300nm |
850nm |
1300nm |
850nm |
|
OM1 62.5/125μm |
≤2.7 |
≤0.6 |
- |
- |
≥200 |
≥600 |
275 |
550 |
- |
OM2 50/125μm |
≤2.5 |
≤0.7 |
- |
- |
≥500 |
≥500 |
550 |
550 |
- |
OM3 50/125μm |
≤2.3 |
≤0.6 |
- |
- |
≥1500 |
≥500 |
1000 |
600 |
300 |
OM4 50/125μm |
≤2.3 |
≤0.6 |
- |
- |
≥3500 |
≥500 |
1000 |
600 |
550 |
OS1 9/125μm |
- |
- |
≤0.34 |
≤0.20 |
- |
- |
- |
- |
- |
OS2 9/125μm |
- |
- |
≤0.34 |
≤0.22 |
- |
- |
- |
- |
Part Number | Fibre Count | Outer Diameter (mm) |
Loose Tube Diameter (mm) |
Cable Weight (kg/km) |
Bend Radius | |
Short (mm) |
Long (mm) |
|||||
3147-31006OS2CL WJL |
6 |
9.3 |
3.3 |
103 |
20D |
10D |
3147-31024OS2CL WJL |
24 |
9.3 |
3.3 |
103 |
20D |
10D |