Norden Category 3 U/UTP cable exceeds Category 3/Class C specification. It is tested up to 16 MHz frequency range. These cables are used for voice and data communications and can handle application bandwidths up to 16 MHz. Other uses for these cables include internal use on customer premises for the interconnection of telephone key systems, PBX and intercom systems.
Conductor |
Bare Copper |
Insulation |
PP (Polypropylene) |
Rip Cord |
Optional |
Outer Jacket |
PVC & LSZH (Optional) |
Jacket Colour |
Gray |
Characteristic | Value |
Conductor Size |
24 AWG |
Nom. Insulation Thickness |
0.15 mm |
Outer Cable Diameter |
4.4 mm |
Max. Recommended Pulling Tension |
66.7 N |
Min. Bend Radius/ Minor Axis |
25.4 mm |
Operating Temperature |
-20 °C to +80 °C |
Characteristic | Unit | Value |
Nom. Conductor DC Resistance @ 20Co |
Ω/km |
92.1 |
Max. Conductor DC Resistance @ 20Co |
Ω/100m |
9.38 |
Nom. Velocity of Propagation |
% |
70 |
Nom. Delay |
ns/m |
4.9 |
Max. Operating Voltage |
V rms |
300 |
Freq. (MHz) | Max. Attenuation (dB/100m) | Min. NEXT (dB) | Min. SRL (dB) |
1 |
2.56 |
41.0 |
12.0 |
4 |
5.58 |
32.0 |
12.0 |
8 |
8.50 |
27.0 |
12.0 |
10 |
9.71 |
26.0 |
12.0 |
16 |
13.10 |
23.0 |
9.96 |
No. | Color |
1 |
White/Blue Stripe & Blue |
2 |
White/Orange Stripe & Orange |
Part Number | Description | Weight (Kg) |
211-00028002X |
2 Pair 24 AWG Cat 3 U/UTP Non bonded Pair Cable CMR PVC, 305m |
5.9 |