2 Pair 16 AWG Unshielded Paired Cable

2 Pair 16 AWG Unshielded Paired Cable

The Unshielded Paired Cable from NORDEN is suitable to use within Audio, Control and Instrumentation purpose. The cable is constructed with PE insulation and PVC/LSZH Outer Jacket.    

The Unshielded Paired Cable from NORDEN is suitable to use within Audio, Control and Instrumentation purpose. The cable is constructed with PE insulation and PVC/LSZH Outer Jacket.    

       Conductor

                  Stranded  Tinned Copper

         Shielding

                       Unshielding

       Jacket Colour

                 Grey



       Insulation

                 PE(Polyethylene)

        Outer Jacket

                    PVC/LSZH

      Rip Cord

               Yes

 

PHYSICAL CHARACTERISTICS

CharacteristicValue

No. of Pair

2

Conductor Size

16 AWG 26x0.25 mm

Insulation Thickness

2.1 ± 0.05 mm

Nom. Jacket Thickness

0.65 mm

Nom. Overall Cable Diameter

8.2 ± 0.3 mm

Min. Bending Radius Minor Axis

123 mm

Operating Temperature
-20ºC to +60ºC

Max. Recommended Pulling Tension

260N

 


ELECTRICAL CHARACTERISTICS

CharacteristicUnitValue

Capacitance Cond. to Cond. 

pF/m

60±15

Nom. Conductor DCR @20°C

Ω/km

14.7

Max. Recommended Current @ 20°C
Amps
10.0
Max. Operating Voltage  UL
V300

Sparker Test

VAC

3000

Nom. Characteristics Impedance
Ω
90±15

MECHANICAL CHARACTERISTICS

CharacteristicValue

Test Material

PVC/LSZH

Before Tensile Strength (Mpa)

13.8

Aging Elongation (%)

100

After Tensile Strength (Mpa)

10.35

Aging Elongation (%)

75

Cold Bend (-20±°C x 4 hrs)

No Crack

INSULATION COLOUR CODE

Individual PairColour

Pair1

Black/Red

Pair2
Black/White
Part NumberDescription

72-3102161

 2 Pair 16 AWG Unshielded Paired Cable PVC, 305m

72-3102162

2 Pair 16 AWG Unshielded Paired Cable LSZH, 305m