MAXPOWER Series is a small to medium power transformer-less UPS of CellNor. This series has Rack/Tower convertible design and a high output power factor at 0.9PF. It has a Hot-Swappable Battery and support Economic (ECO) Operation Mode. CN7002MPI-RM/CN7002MPE-RM is a true online double conversion UPS with efficiency up to 90%.
MAXPOWER Series is a small to medium power transformer-less UPS of CellNor. This series has Rack/Tower convertible design and a high output power factor at 0.9PF. It has a Hot-Swappable Battery and support Economic (ECO) Operation Mode. CN7002MPI-RM/CN7002MPE-RM is a true online double conversion UPS with efficiency up to 90%.
Model | CN7002MPI-RM/CN7002MPE-RM | ||
Capacity | VA | 2000 | |
Watts | 1800 | ||
Phase | Single phase with ground | ||
Input | Normal Voltage | 208/220/230/240Vac | |
Input Voltage Range | 110~300Vac (176~264Vac @ 100% load) | ||
Frequency Range | 40~70Hz(50/60Hz Auto Sensing | ||
Power Factor | ≥0.99 @Nominal voltage(100% load) | ||
Output | Output Voltage | 208/220/230/240Vac | |
Power Factor | 0.9 | ||
Voltage Regulation | ±1% | ||
Frequency range (Synchronized range) | 46~54Hz/56~64Hz | ||
Frequency range (Batt.mode) | 50Hz/60Hz±0.1Hz | ||
Current crest ratio | 3:1 | ||
Harmonic Distortion (THDv) | ≤3% THD(Linear load) | ||
≤5% THD(Non-linear load) | |||
Transfer Time | AC to DC | Zero | |
Inverter to Bypass | 4ms(Typical) | ||
Waveform | Pure Sinewave | ||
Efficiency | AC Mode | 91% | |
Battery Mode | 87% | ||
Battery | Internal | Battery Type | 12V/9AH |
Numbers | 6 | ||
Typical Recharging Time | 4 hours recover to 90% capacity | ||
Charging current(max.) | 1.0A | ||
Charging Voltage | 82.2Vdc ±1% | ||
Battery | External | Battery Number | 6 |
Battery Voltage | 82.2Vdc ±1% | ||
Charging current | 12A | ||
Indicators | LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode and Fault indicators | |
Alarm | Battery Mode | Beeping every 4 seconds | |
Battery Low | Beeps every second | ||
Overload | Beeps twice every second | ||
Fault | Continuously beeping | ||
Physical | Dimension W x D x H (mm) | Standard model | 440 x 600 x 86.5 (2U) |
Long run model | 440 x 600x 86.5 (2U) | ||
Net Weight (kg) | Standard model | 19.5/25 | |
Long run model | 10.5 | ||
Environment | Humidity | 20-95% RH @ 0-40°C (Non-condensing) | |
Noise level | <50dB @ 1 Meter | ||
Management | Smart RS232/USB | Supports Windows® 2000/2003/XP/Vista/2008 Windows® 7/8 Linux, FreeBSD and MAC | |
Optional SNMP | Power management from SNMP manager and web browser | ||
Standards | Safety | IEC/EN62040-1,IEC/EN62477-1 | |
EMC | IEC/EN62040-2,IEC61000-4-2,IEC61000-4-3,IEC61000-4-4,IEC61000-4-5,IEC61000-4-6,IEC61000-4-8 IEC61000-4-11,IEC61000-2-2 |
EXTERNAL BATTERY PACK | ||
Model | CNBC00272CR | |
Battery Type | VRLA (Valve Regulated Lead Acid Battery - SMF) | |
Typical battery recharging time | 6~8 hours (to 90% of full capacity) | |
Typical Battery Life | 3~5 years, depend on discharging cycle and ambient temperature | |
System Voltage | 72Vdc | |
Battery quantity | 12 | |
Capacity | 9Ah/12V (7Ah/12V optional | |
PHYSICAL | ||
Dimension W x D x H (mm) | 440 x 710 x 86.5 (2U)
| |
Net weight(kg) | 44.0
| |
ENVIRONMENT | ||
Operating environment | 0°C~40°C | |
Relative humidity | 0~95% (Non condensing) | |
Noise Level | <40dB at 1 Meter |
Part Number | Description | ||
CN7002MPI-RM | 2kVA Online Transformerless Rack Mount UPS (Internal battery) | ||
CN7002MPE-RM | 2kVA Online Transformerless Rack Mount UPS (External battery) | ||
CNBC00272CR | 72VDC Rack Mount Battery Pack |
Part Number | Description | ||
CNRM0110R | Rack Mounting Rail Kit for 1-10kVA RM UPS | ||
CNRM0110BPR | Battery Pack Rack Mounting Rail Kit for 1-10kVA RM UPS | ||
CNS02 | Mini SNMP Card |