Norden's Ultra power series 50-80 kVA UPS is an online double conversion UPS that features three-phase in both input and output and a unity output power factor.This has a tower design which features strict voltage regulation and parallel operation of 6 units that makes it ideal for data centers and other critical bussiness applications.
Norden's Ultra power series 50-80 kVA UPS is an online double conversion UPS that features three-phase in both
input and output and a unity output power factor.This has a tower design which features strict voltage regulation
and parallel operation of 6 units that makes it ideal for data centers and other critical bussiness applications.
Model | CN93350U/CN93350U-5L | CN93360U/CN93360U-5L | CN93380U/CN93380U-5 | |
Capacity | kVA | 50 | 60 | 80 |
Watts | 50K | 60K | 80K | |
Input |
Normal Voltage | 380/400/415Vac (3Ph+N+PE)
|
||
Operating voltage range | 138~305Vac for 40% Load; 305~485Vac for Full Load | |||
Harmonic distortion(THDi) | <3%(100% linear load) | |||
Operating frequency range | 40~70Hz | |||
Power factor | ≥0.99 | |||
Bypass voltage range | 220Vac Max.Voltage:+25% (optional +10%,+15%,+20%) 230Vac Max.Voltage:+20%(optional +10%,+15%) 240Vac Max.Voltage:+15%(optional +10%) Min.Voltage:-45%(optional -20%,-30%) | |||
Bypass Frequency range | Frequency synchronize tracing range:±10% | |||
Generator input | Support | |||
Output |
Rated voltage | 380/400/415Vac (3Ph+N+PE)
|
||
Power factor | 1.0 | |||
Voltage regulation | ±1% | |||
Frequency Line mode | ±1%/±2%/±4%/±5%/±10% of the rated frequency (Optional) | |||
Frequency Bat. mode | 50/60(±0.1)Hz | |||
Crest factor | 3:1 | |||
Harmonic distortion (THDv) | ≤2% with linear load, ≤4% with non-linear load | |||
Efficiency | 95.5% | |||
Output Waveform | Pure Sine Wave
| |||
Battery |
Rated voltage | ±180/±192/±204/±216/±228/±240/±252/±264/±276/±288/±300Vdc(30/32/34/36/38/40/42/44/46/48/50pcs)
|
||
Charging current
(Charging current can be
set according to the battery
capacity installed)
| 20A |
40A |
||
System Features |
Transfer time | Mains to battery:0ms; Inverter to bypass:0ms
|
||
Overload Line mode | ≤110%: Overload 60min, ≤150%: Overload 1min, >150% 1.2s turn to bypass mode immediately | |||
Overload Bypass mode | 30°C: 135% Overload long term; 40°C: 125% Overload long term >1000%, 100ms | |||
Backfeed Protection | Support | |||
Alarm | Overload, utility abnormal, UPS fault, battery low, etc | |||
Protection | Short circuit, overload, over-temperature, battery low, fan fault alarm | |||
Remote LCD | Support | |||
Communication | USB, RS232, RS485, Parallel port,dry contact, Intelligent slot, LBS, SNMP card (optional), Relay card (optional) | |||
Environment |
Operating temperature | 0~40°C
|
||
Storage temperature | -25~55°C | |||
Humidity range | 0~95% (Non-condensing)
| |||
Altitude | <1500m | |||
Noise level | <55dB |
<58db |
<60db | |
Physical |
Dimension WxDxH(mm) | 250x828x868 442x850x1200 |
||
Net Weight (kg) | 80
|
83 |
114 | |
Standards |
Safety | IEC/EN62040-1,IEC/EN62477-1
|
||
EMC | IEC/EN 62040-2 (IEC 61000-2-2, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC61000-4-11)
|
Part Number | Description | ||
CN93350U | 50kVA Double Conversion Transformer-less 3/3 UPS (External Battery) | ||
CN93360U | 60kVA Double Conversion Transformer-less 3/3 UPS (External Battery) | ||
CN93380U | 80kVA Double Conversion Transformer-less 3/3 UPS (External Battery) | ||
CN93350U-5L | 50kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) | ||
CN93360U-5L | 60kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) | ||
CN93380U-5L | 80kVA Double Conversion Transformer-less 3/3 UPS with 5inch LCD display (External Battery) |
Part Number | Description | ||
CNS01 | SNMP Card |