Norden Cat 6 S/FTP patch cords are manufactured using high quality shielded four pair Category 6 stranded cable, and feature cable strain relief boots with a plug latch protection cap. This patch cord when used with high performance Norden Category 6 connectivity (Solid shielded cable, patch panels and work area outlets), provide superior performance capabilities of high bandwidth (Gigabit 1000Base-T and 1000Base-Tx) applications support. This is fully backward compatible to Category 5e (Class D) products backup. Each patch cord is tested with Fluke tester and individual cover include with the report. Norden Category 6 Patch cord is tested for transmission frequencies of up to 250 MHz.
IEEE 802.af and IEEE 802.3at for PoE applications
ANSI/TIA-568.2-D and ISO/IEC-11801 (2nd Edition),
IEC 61156-2, EN 50173; EN 50288-6-2 Category 6 standard
Basic Cable Conductor |
Stranded Bare Annealed Copper |
Wire Insulation |
SFS PE |
Number Of Insulated Conductors |
8 |
Wire Gauge |
26 AWG |
Colour Code Of Pairs |
Blue x White, Orange x White, Green x White, Brown x White |
Individual Pair Shield |
Polyester-Aluminium foil |
Overall Shield |
Tinned Copper, Braid |
Braid Shield Coverage |
40% |
Drain Wire |
No |
Outer Jacket and Boots |
LSZH Low Smoke Zero Halogen or PVC |
Jacket and Boot Colour |
Per Requirement |
Standard Surface Marking |
Includes Norden P/N, cable description |
Cable O.D. |
5.7 ± 0.2 mm |
Bend Radius |
> 23 mm Without load |
Storage Temperature |
-20 °C to +80 °C |
Temperature Operating Range |
-20 °C to +75 °C |
Flame Test |
IEC 60332-1 |
Halogen Content In LSZH Cables |
Null |
Wire Scheme |
T568B |
Impedance @ 1-100MHz |
100 ±15 Ω |
Impedance @ 100-250MHz |
100 ±15 Ω |
Conductor Resistance |
< 73 Ω/km |
Contact Resistance |
20 MΩ max. |
Resistance Unbalance |
2 % max. |
Voltage Rating |
72 Vdc |
Dielectric Strength |
1 KV/min. rms |
Ampacity |
1.0 Amps max. |
Insulation Resistance |
150 MΩ/Km |
Transfer Impedance |
N/A |
Pair To Ground Capacitance Unbalance |
3.3 nF/Km nom. |
Cable To Plug Tensile Strength |
96 N min. |
Pulling Force |
10 N max. |
Durability |
1000 Mating Cycles |
Propagation Delay 1-250MHz |
< 25 ns/100m |
Freq. MHz |
NEXT(dB) min. | RL(dB) min. | ||
2m cord | 5m cord | 10m cord | ||
1 | 68.0 | 68.0 | 68.0 | 20.0 |
4 | 65.0 | 65.0 | 65.0 | 21.8 |
10 | 64.8 | 64.2 | 62.8 | 22.5 |
20 | 60.9 | 58.6 | 57.2 | 23.4 |
30 | 56.2 | 54.9 | 53.6 | 23.0 |
60 | 50.4 | 49.2 | 48.1 | 20.0 |
100 | 46.4 | 45.2 | 44.4 | 18.0 |
125 | 44.5 | 43.5 | 42.7 | 17.0 |
150 | 43.2 | 42.2 | 41.1 | 16.2 |
200 | 40.8 | 39.6 | 39.1 | 15.0 |
250 | 38.8 | 37.9 | 37.6 | 13.8 |
Part Number | Description | Length |
127-31501X |
Category 6 S/FTP Patch Cord PVC 01m |
1m |
127-31502X |
Category 6 S/FTP Patch Cord PVC 02m |
2m |
127-31503X |
Category 6 S/FTP Patch Cord PVC 03m |
3m |
127-31505X |
Category 6 S/FTP Patch Cord PVC 05m |
5m |
127-31510X |
Category 6 S/FTP Patch Cord PVC 10m |
10m |
127-31515X |
Category 6 S/FTP Patch Cord PVC 15m |
15m |
127-31520X |
Category 6 S/FTP Patch Cord PVC 20m |
20m |
127-31525X |
Category 6 S/FTP Patch Cord PVC 25m |
25m |
127-325H5X | Category 6 S/FTP Patch Cord LSZH 0.5m | 0.5m |
127-32501X |
Category 6 S/FTP Patch Cord LSZH 01m |
1m |
127-325F5X | Category 6 S/FTP Patch Cord LSZH 1.5m | 1.5m |
127-32502X |
Category 6 S/FTP Patch Cord LSZH 02m |
2m |
127-32503X |
Category 6 S/FTP Patch Cord LSZH 03m |
3m |
127-32505X |
Category 6 S/FTP Patch Cord LSZH 05m |
5m |
127-32510X |
Category 6 S/FTP Patch Cord LSZH 10m |
10m |
127-32515X |
Category 6 S/FTP Patch Cord LSZH 15m |
15m |
127-32520X |
Category 6 S/FTP Patch Cord LSZH 20m |
20m |
127-32525X |
Category 6 S/FTP Patch Cord LSZH 25m |
25m |